Zingaki Izinhlobo Ze-X-Ray Tube Ezikhona?

Zingaki Izinhlobo Ze-X-Ray Tube Ezikhona?

Impendulo emfushane: kunezinhlobo ezimbili eziyisisekelo—i-anode emilefuthii-anode ejikelezayoAmashubhu e-X-ray. Kodwa lokho kumane kuyisiqalo. Uma usucabangele ukusetshenziswa, isilinganiso samandla, usayizi wendawo egxile, kanye nendlela yokupholisa, ukwehluka kuyanda ngokushesha.

Uma ufuna ukutholaAmashubhu e-X-rayNgemishini yokuthwebula izithombe zezokwelapha, izinhlelo ze-NDT zezimboni, noma imishini yokuhlola ezokuphepha, ukuqonda lokhu kwahlukana akuyona into ongayikhetha. Ipayipi elingalungile lisho ikhwalithi yesithombe ebucayi, ukwehluleka kwangaphambi kwesikhathi, noma ukungahambisani kwemishini.

Ake sikuchaze kahle.

 

Izinhlobo Ezimbili Eziyinhloko Ze-X-Ray Tube

Amashubhu e-X-Ray e-Anode amile

Umklamo olula. I-anode (ithagethi) ihlala iqinile ngenkathi ama-electron ehlasela ithrekhi eyodwa yokugxila. Ukushabalaliswa kokushisa kulinganiselwe, okuvala amandla okukhipha.

Lapho zisebenza kahle khona:

  • Amayunithi e-X-ray yamazinyo
  • I-X-ray ephathekayo
  • Ukuhlolwa kwezimboni okwenziwa ngesivinini esiphansi
  • Izithombe zezilwane

Izinzuzo? Izindleko eziphansi, usayizi omncane, ukulungiswa okuncane. Umehluko uwukuthi amandla okushisa—wacindezele kakhulu futhi uzoshisa udlule endaweni ehlosiwe.

Izinhlobo ezijwayelekile: 50-70 kV, indawo yokugxila engu-0.5-1.5 mm, indlu epholiswe uwoyela.

Amashubhu e-X-Ray e-Anode ajikelezayo

Ihhashi elisebenzayo le-radiology yesimanje. Idiski ye-anode ijikeleza ku-3,000-10,000 RPM, isakaza ukushisa endaweni enkulu kakhulu. Lokhu kuvumela ukukhishwa kwamandla aphezulu kanye nezikhathi zokuchayeka isikhathi eside ngaphandle kokulimala kokushisa.

Lapho bebusa khona:

  • Izikena ze-CT
  • Izinhlelo ze-Fluoroscopy
  • I-Angiography
  • I-radiography ephezulu kakhulu

Ubunjiniyela buyinkimbinkimbi kakhulu—amabheringi, ama-rotor assemblies, ama-motor anesivinini esikhulu—okusho izindleko eziphakeme kanye nokucabangela ukunakekelwa okwengeziwe. Kodwa ngezinhlelo zokusebenza ezidinga amandla amaningi, akukho okunye okungathatha indawo.

Izinhlobo ezijwayelekile: 80-150 kV, indawo yokugxila engu-0.3-1.2 mm, umthamo wokugcina ukushisa ongu-200-800 kHU.

Ngale Kwezisekelo: Izinhlobo Ezikhethekile Ze-X-Ray Tube

Amashubhu e-Microfocus X-Ray

Izindawo zokugxila ezincane njenge-5-50 microns. Zisetshenziswa ekuhlolweni kwe-PCB, ekuhlaziyweni kokwehluleka kwe-elekthronikhi, kanye ne-CT yezimboni enesinqumo esiphezulu. Ukuthwebula izithombe zokukhulisa kudinga leli zinga lokunemba.

Amapayipi e-Mammography

Izinhloso ze-Molybdenum noma ze-rhodium esikhundleni se-tungsten. Ibanga le-kV eliphansi (25-35 kV) lenzelwe ukungafani kwezicubu ezithambile. Izidingo zokulawula eziqinile ziyasebenza.

Amashubhu Anamandla Aphezulu e-CT

Yakhelwe ukujikeleza okuqhubekayo kanye nokujikeleza okusheshayo kokushisa. Ama-bearings ensimbi ewuketshezi kumamodeli aphezulu andisa impilo yesevisi. Amazinga okushabalalisa ukushisa angu-5-7 MHU/min avamile kuma-scanner esizukulwane samanje.

Amapayipi e-NDT Ezimboni

Yakhelwe izindawo ezinzima—ukushisa okweqile, ukudlidliza, uthuli. Izinketho zomsebe oqondisayo kanye nowe-panoramic. I-voltage isukela ku-100 kV kuma-alloy alula afinyelela ku-450 kV kuma-castings ensimbi esindayo.

Amapharamitha Abalulekile Abathengi Okufanele Bawahlole

Ipharamitha Kungani Kubalulekile
I-Tube Voltage (kV) Inquma ikhono lokungena
I-Tube Current (mA) Kuthinta isikhathi sokuvezwa kanye nokukhanya kwesithombe
Usayizi Wendawo Egxile Okuncane = izithombe ezibukhali, kodwa ukubekezelela ukushisa okuphansi
Umthamo Wokushisa we-Anode (HU/kHU) Kukhawulela isikhathi sokusebenza okuqhubekayo
Izinto Eziqondiwe I-Tungsten (ejwayelekile), i-Molybdenum (i-mammo), i-Copper (yezimboni)
Indlela Yokupholisa Uwoyela, umoya ophoqelelwe, noma amanzi—kuthinta umjikelezo womsebenzi
Ukuhambisana Kwezindlu Kumelwe kufane nokufakwa kwe-OEM kanye nemininingwane yesixhumi

Okufanele Uqinisekise Ngaphambi Koku-oda

Ukuthola izinsizaAmashubhu e-X-rayakufani nokuthenga izingxenye zezimpahla. Imibuzo embalwa okufanele uyibuze:

  • I-OEM noma i-aftermarket?Amashubhu e-Aftermarket angaletha ukonga kwezindleko okungu-30-50%, kodwa qinisekisa izitifiketi zekhwalithi.
  • Ukumbozwa kwewaranti– Izinyanga ezingu-12 ziyindinganiso; abanye abahlinzeki banikeza isikhathi esengeziwe kumayunithi e-anode ajikelezayo.
  • Ukuthobela imithetho– Imvume ye-FDA 510(k) yezimakethe zezokwelapha zase-US, uphawu lwe-CE eYurophu, i-NMPA yaseShayina.
  • Isikhathi esiholayo– Amashubhu e-CT anamandla amakhulu avame ukuba nemijikelezo yokukhiqiza yamasonto angu-8-12.
  • Ukusekela kwezobuchwepheshe- Isiqondiso sokufaka, ukuqinisekiswa kokuhambisana, ukuhlaziywa kokwehluleka.

Ufuna Umhlinzeki We-X-Ray Tube Othembekile?

SihlinzekaAmashubhu e-X-raykwezinhlelo zokusebenza zezokwelapha, zezimboni, kanye nezokuphepha—i-anode engashintshi, i-anode ejikelezayo, i-microfocus, kanye nokucushwa okukhethekile. Ikhwalithi elingana ne-OEM. Amanani ancintisanayo kumashubhu okufaka esikhundleni kanye nama-insert assemblies aphelele.

Sithumelele imodeli yakho yemishini kanye nemininingwane yeshubhu yamanje. Sizoqinisekisa ukuhambisana futhi sinikeze ikhotheshini zingakapheli amahora angu-48.


Isikhathi sokuthunyelwe: Disemba-29-2025