Incazelo emfushane:

Uhlobo: Ishubhu ye-anode emile ye-x-ray
Isicelo: Okweyunithi ye-radiography yamazinyo
Imodeli: RT11-0.4-70
Ilingana ne-TOSHIBA D-041

Kufakwe endaweni ebiyelwe efanayo ne-high voltage transformer


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Incazelo

I-RT11-0.4-70 Stationary anode X-Ray Tube yakhelwe ikakhulukazi iyunithi ye-x-ray yamazinyo yangaphakathi emlonyeni futhi iyatholakala ku-voltage yeshubhu ene-DC.
I-RT11-0.4-70 tube inokugxila okukodwa.
Ishubhu yekhwalithi ephezulu edidiyelwe enomklamo wengilazi inendawo eyodwa ebekwe kahle kakhulu kanye ne-anode eqinisiwe. Umthamo ophezulu wokugcina ukushisa kwe-anode uqinisekisa ububanzi bezinhlelo zokusebenza zokufakwa kwamazinyo ngaphakathi emlonyeni. I-anode eklanywe ngokukhethekile inika amandla izinga eliphezulu lokulahla ukushisa eliholela ekusebenzeni okuphezulu kwesiguli kanye nempilo ende yomkhiqizo. Isivuno esiqhubekayo somthamo omkhulu phakathi nayo yonke impilo yeshubhu siqinisekiswa yithagethi ye-tungsten ephakeme kakhulu. Ukulula kokuhlanganiswa emikhiqizweni yesistimu kwenziwa lula ukwesekwa kwezobuchwepheshe.

Izinhlelo zokusebenza

I-RT11-0.4-70 Stationary anode X-Ray Tube yakhelwe ikakhulukazi iyunithi ye-x-ray yamazinyo yangaphakathi emlonyeni futhi iyatholakala ku-voltage yeshubhu ene-DC.

Idatha yobuchwepheshe

I-Maximum Tube Voltage 70kV
I-MaximumTube Yamanje 9mA
Amandla amakhulu (ku-1.0s) 430W
Isilinganiso esiphezulu sokupholisa i-anode 110W
I-Max.Okuqukethwe Kokushisa kwe-Anode 4.3kJ
Izici ze-Filament .Ifmax=3.0A,Uf=3.2±0.5V
Indawo okugxilwe kuyo 0.4(IEC 60336 2005)
I-Engeli eqondiwe 12°
Okuqondisiwe I-Tungsten
Uhlobo lwe-Cathode I-W filament
Ukuhlunga Okuphakade Okuncane. 0.5mmAl/50 kV(IEC60522/1999)
Ubukhulu 67mm ubude by 30mm ububanzi
Isisindo 100 amagremu

Izithombe ezinemininingwane

I-KL11-0.4-70

Izici

Inzuzo Yokuncintisana

Umthamo wokugcina ukushisa kwe-anode nokupholisa
Isivuno somthamo ophezulu njalo
Ukuphila okuhle kakhulu

Ukugcina uhlelo lwesinongo

Ngaphambi kokusetshenziswa, inkathi ishubhu ngokuhambisana neshejuli yesinongo enikezwe ngezansi kuze kube yilapho kutholakala amandla kagesi eshubhu adingekayo. Isibonelo esinikiwe - sidinga ukubuyekezwa ngumkhiqizi futhi sicaciswe eshidini ledatha lengxenye:

Ishejuli yesinongo yokuqala engenayo kanye nesinongo sesikhathi sokungenzi lutho (ngaphezu kwezinyanga eziyi-6) Isifunda: AC/DC (Kusekelwe maphakathi)

Lapho ithubhu lamanje lingagxilile kusinongo, vala ngokushesha i-voltage yeshubhu futhi ngemva kwesikhawu semizuzu emi-5 noma ngaphezulu, wandise i-voltage yeshubhu kancane kancane ukusuka ku-voltage ephansi ngenkathi uqinisekisa ukuthi ishubhu lamanje lizinzile. Ukusebenza kwe-voltage okumelana neyunithi yeshubhu kuzokwehliswa njengoba isikhathi sokuchayeka kanye nenani lokusebenza likhula. Ukulandela umthelela okufana nebala kungase kuvele endaweni eqondiswe kwishubhu le-x-ray ngokuphuma kancane phakathi nesinongo. Lezi zimo ziyinqubo eyodwa yokubuyisela ukusebenza kwe-voltage emile ngaleso sikhathi. Ngakho-ke, uma isebenza ngokuzinzile ku-voltage ephezulu yeshubhu yesinongo esilandela kubo, iyunithi yeshubhu ingasetshenziswa ngaphandle kokuphazamiseka ekusebenzeni kwayo kagesi esetshenziswayo.


  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: Amaviki angu-1 ~ 2 ngokwenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umyalezo wakho lapha futhi usithumelele wona