China Dental X-ray Tube Toshiba D-041 Umkhiqizi Nomhlinzeki |I-Sailray
Ishubhu ye-X-ray Yamazinyo i-Toshiba D-041

Ishubhu ye-X-ray Yamazinyo i-Toshiba D-041

Ishubhu ye-X-ray Yamazinyo i-Toshiba D-041

Incazelo emfushane:

Uhlobo: Ishubhu ye-anode emile ye-x-ray
Isicelo: Okweyunithi ye-radiography yamazinyo
Imodeli: RT11-0.4-70
Ilingana ne-TOSHIBA D-041

Kufakwe endaweni ebiyelwe efanayo ne-high voltage transformer


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Incazelo

I-RT11-0.4-70 Ishubhu ye-anode emile ye-X-Ray iklanyelwe ngokukhethekile iyunithi ye-x-ray yamazinyo yangaphakathi emlonyeni futhi itholakala ku-voltage yeshubhu ene-DC.
I-RT11-0.4-70 tube inokugxila okukodwa.
Ishubhu yekhwalithi ephezulu edidiyelwe enomklamo wengilazi inendawo eyodwa ebekwe kahle kakhulu kanye ne-anode eqinisiwe.Umthamo ophezulu wokugcina ukushisa kwe-anode uqinisekisa ububanzi bezinhlelo zokusebenza zokufakwa kwamazinyo ngaphakathi emlonyeni.I-anode eklanywe ngokukhethekile inika amandla izinga eliphezulu lokulahla ukushisa eliholela ekusebenzeni okuphezulu kwesiguli kanye nempilo ende yomkhiqizo.Isivuno esiqhubekayo somthamo omkhulu phakathi nayo yonke impilo yeshubhu siqinisekiswa yithagethi ye-tungsten ephakeme kakhulu.Ukulula kokuhlanganiswa emikhiqizweni yesistimu kwenziwa lula ukwesekwa kwezobuchwepheshe.

Izinhlelo zokusebenza

I-RT11-0.4-70 Ishubhu ye-anode emile ye-X-Ray iklanyelwe ngokukhethekile iyunithi ye-x-ray yamazinyo yangaphakathi emlonyeni futhi itholakala ku-voltage yeshubhu ene-DC.

Idatha yobuchwepheshe

I-Maximum Tube Voltage 70kV
I-MaximumTube Yamanje 9mA
Amandla amakhulu (ku-1.0s) 430W
Isilinganiso esiphezulu sokupholisa i-anode 110W
I-Max.Okuqukethwe Kokushisa kwe-Anode 4.3kJ
Izici ze-Filament .Ifmax=3.0A,Uf=3.2±0.5V
Indawo okugxilwe kuyo 0.4(IEC 60336 2005)
I-Engeli eqondiwe 12°
Okuqondisiwe I-Tungsten
Uhlobo lwe-Cathode I-W filament
Ukuhlunga Okuphakade Okuncane.0.5mmAl/50 kV(IEC60522/1999)
Ubukhulu 67mm ubude by 30mm ububanzi
Isisindo 100 amagremu

Izithombe ezinemininingwane

I-KL11-0.4-70

Izici

Inzuzo Yokuncintisana

Umthamo wokugcina ukushisa kwe-anode nokupholisa
Isivuno somthamo ophezulu njalo
Ukuphila okuhle kakhulu

Ukugcina uhlelo lwesinongo

Ngaphambi kokusetshenziswa, inkathi ishubhu ngokuhambisana neshejuli yesinongo enikezwe ngezansi kuze kube yilapho kutholakala amandla kagesi eshubhu adingekayo.Isibonelo esinikiwe - sidinga ukubuyekezwa ngumkhiqizi futhi sicaciswe eshidini ledatha lengxenye:

Ishejuli yesinongo yokuqala engenayo kanye nesinongo sesikhathi sokungenzi lutho (ngaphezu kwezinyanga eziyi-6) Isifunda: AC/DC (Isekelwe maphakathi)

Lapho ithubhu lamanje lingagxilile kusinongo, vala ngokushesha i-voltage yeshubhu futhi ngemva kwesikhawu semizuzu emi-5 noma ngaphezulu, wandise i-voltage yeshubhu kancane kancane ukusuka ku-voltage ephansi ngenkathi uqinisekisa ukuthi ishubhu lamanje lizinzile.Ukusebenza kwe-voltage okumelana neyunithi yeshubhu kuzokwehliswa njengoba isikhathi sokuchayeka kanye nenani lokusebenza likhula.Ukulandela umthelela okufana nebala kungase kuvele endaweni eqondiswe kwishubhu le-x-ray ngokuphuma kancane phakathi nesinongo.Lezi zimo ziyinqubo eyodwa yokubuyisela ukusebenza kwe-voltage emile ngaleso sikhathi.Ngakho-ke, uma isebenza ngokuzinzile ku-voltage yeshubhu ephezulu yesinongo elandela bona, iyunithi yeshubhu ingasetshenziswa ngaphandle kokuphazamiseka ekusebenzeni kwayo kagesi esetshenziswayo.


  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umlayezo wakho lapha futhi usithumelele wona