I-China Medical X-ray Collimator Manual X-ray Collimator SR102 Umkhiqizi Nomphakeli |I-Sailray
I-Medical X-ray Collimator Manual X-ray Collimator SR102

I-Medical X-ray Collimator Manual X-ray Collimator SR102

I-Medical X-ray Collimator Manual X-ray Collimator SR102

Incazelo emfushane:

Izici
Ifanele izinto ezijwayelekile zokuxilonga ze-X-ray ne-tube voltage engu-150kV
Indawo evezwa ngamaX-reyi inonxande.
Lo mkhiqizo uthobelana namazinga afanele kazwelonke nawemboni
Usayizi omncane
Ukusebenza okuthembekile, ukonga.
 Ukusebenzisa ungqimba olulodwa namasethi amabili amaqabunga omthofu kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela ama-X-ray
Ukulungiswa kwendawo yokuthela kwenziwa ngesandla, futhi inkambu yokuthela imisebe ihlale ilungiseka.
Inkambu yokukhanya ebonakalayo ithatha ama-LED ama-bulb akhanya kakhulu, anempilo ende yesevisi
Isekhethi yokulibaziseka yangaphakathi ingacisha isibani ngokuzenzakalela ngemva kwamasekhondi angu-30 okukhanya, futhi ingacisha isibani mathupha phakathi nesikhathi sokukhanya ukuze kwelule impilo yesibani futhi yonge amandla.
Ukuxhumana kwemishini phakathi kwalo mkhiqizo neshubhu ye-X-ray kulula futhi kuthembekile, futhi ukulungiswa kulula


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Imingcele yezobuchwepheshe eyinhloko nezinkomba

Ukuvuza kwe-X-ray: <1mGy/h (150kV, 4mA)
Ibanga elisuka lapho kugxilwe khona ishubhu ye-X-ray ukuya endaweni yokufaka isikhawulo se-beam: 60mm (ingalungiswa ngokuvumelana namashubhu ahlukene)
Ukuvumelana kwenkambu yokukhanya: <2%@SID
Ukuhlunga okungokwemvelo: 1mmAl/75kV

Ongakukhetha:
 Izinketho Zokuhlunga Zangaphandle Ezithuthukisiwe
Isixhumi esibonakalayo sikagesi esikhethekile
Isixhumi esibonakalayo sebhola leshubhu

Imingcele yezobuchwepheshe

I-Max Voltage

150KV

Ibanga eliphezulu lenkambu ye-X-ray

440mmx440mm (SID=100cm)

Ukukhanya okumaphakathi kwenkambu yokukhanya

> 160 lux

Isilinganiso sokungafani somphetho

> 4:1

Isidingo sokuphakelwa kwamandla kwesibani sokuqagela

24V/100W

Ubude benkambu ye-X-ray ekhanyayo Kanye

30S

Ibanga ukusuka ku-Focal Spot yeshubhu le-X-ray ukuya endizeni yokukhweza ye-collimator SID (mm)(kuyakhetheka)

60

Ukuhlunga(Imvelo) 75kV

1 mml

Ukuhlunga(Okwengeziwe)

Ongakukhetha kwangaphandle

Indlela yokulawula

Imanuwali

Shayela injini

--

Ukulawulwa Kwezimoto

--

Ukutholwa kwesikhundla

--

Amandla okokufaka

I-AC24V

(SID)Itheyiphu yokulinganisa

Ukucushwa Okujwayelekile

Imiyalo ye-laser ephakathi

--

Ubukhulu(mm)(W×L×H)

223x185x87

Isisindo(Kg)

5.5

Isakhiwo

Izinhlelo zokusebenza

Le collimator ye-x-ray ifanele okokusebenza okujwayelekile kwe-X-ray okunamandla omthamo weshubhu ongu-150kV, DR.


  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umlayezo wakho lapha futhi usithumelele wona