I-China Medical X-ray Collimator Manual X-ray beam limitter SR202 Umkhiqizi Nomphakeli | I-Sailray
I-Medical X-ray Collimator Manual X-ray beam limitter SR202

I-Medical X-ray Collimator Manual X-ray beam limitter SR202

I-Medical X-ray Collimator Manual X-ray beam limitter SR202

Incazelo emfushane:

Izici
Ihambisana nemishini yokuxilonga ye-X-ray esebenzisa i-voltage yeshubhu engu-150kV, okuhlanganisa nezinhlelo zedijithali ze-DR kanye nezinhlelo ezivamile
 Inkundla yokuthela ngemisebe ye-X-ray inonxande
Ukuhambisana namazinga afanele kazwelonke nawemboni
Usayizi omncane
Ukuthembeka okuphezulu nokusebenza kwezindleko eziphezulu
Isebenzisa isendlalelo esisodwa, amasethi amabili amaqabunga omthofu kanye nomklamo okhethekile wokuvikela wangaphakathi ukuvimba ama-X ray.
Ukulungiswa kwenkundla yokuthela imisebe kwenziwa ngesandla, kuyalungiseka ngokuqhubekayo
Inkambu yokukhanya ebonakalayo isebenzisa amalambu e-LED
Isekhethi yokulibaziseka eyakhelwe ngaphakathi icima isibani ngokuzenzakalelayo imizuzwana engama-30 ngemuva kokuqaliswa, futhi inketho yezandla yokucisha ukukhanya phakathi nokusebenza nayo iyatholakala. Lezi zici ziklanyelwe ukunweba impilo yesibani futhi kuncishiswe ukusetshenziswa kwamandla.


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Imingcele yezobuchwepheshe eyinhloko nezinkomba

Ukuvuza kwe-X-ray: <1mGy/h (150kV, 4mA)
Leli banga lingalungiswa ngokwethubhu ye-X-ray ethile esetshenzisiwe. Ibanga elijwayelekile lingu-60mm ukusuka lapho kugxilwe khona ishubhu le-X-ray ukuya endaweni ekhwezwayo yesikhawuli sohlaka.
Isikali senkambu yokuthela imisebe: 43cmX43cm (SID=1m)
Indawo encane yokuthela imisebe: <5cmX5cm (SID=1m)
 Ukukhanya kwenkambu yokukhanya okubonakalayo: >140lux (SID=1m)
Ukuvumelana kwenkambu yokukhanya: <2%@SID
Ukuhlunga okungokwemvelo: 1mmAl/75kV
Amandla okokufaka: 24VAC/50W noma 24VDC/50W
 Ubukhulu: 185mm×198mm×145mm (ubude×ububanzi×ubude)
Isisindo: 6.2kg

Ongakukhetha:
Isihlungi esengeziwe sangaphandle
Isixhumi esibonakalayo sikagesi esikhethekile
Isixhumi esibonakalayo sebhola leshubhu
Umugqa wegama owodwa we-laser locator

Imingcele yezobuchwepheshe

I-Max Voltage

150KV

Ibanga eliphezulu lenkambu ye-X-ray

440mm×440mm (SID=100cm)

Ukukhanya okumaphakathi kwenkambu yokukhanya

> 160 lux

Isilinganiso sokungafani somphetho

> 4:1

Isidingo sokuphakelwa kwamandla kwesibani sokuqagela

24V/150W

Ubude benkambu ye-X-ray ekhanyayo Kanye

30S

Ibanga ukusuka ku-Focal Spot yeshubhu le-X-ray ukuya endizeni yokukhweza ye-collimator SID (mm)(kuyakhetheka)

60

Ukuhlunga(Imvelo) 75kV

1 mml

Ukuhlunga(Okwengeziwe)

Ongakukhetha kwangaphandle

Indlela yokulawula

Imanuwali

Shayela injini

--

Ukulawulwa Kwezimoto

--

Ukutholwa kwesikhundla

--

Amandla okokufaka

I-AC24V

(SID)Itheyiphu yokulinganisa

Ukucushwa Okujwayelekile

Imiyalo ye-laser ephakathi

ngokuzikhethela

Ubukhulu(mm)(W×L×H)

185×198×145

Isisindo(Kg)

6.8

Izinhlelo zokusebenza

Le collimator ye-x-ray ifanele amashubhu kagesi angu-150kV, i-DR digital kanye nemishini yokuxilonga ye-X-ray evamile.


  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umyalezo wakho lapha futhi usithumelele wona