I-Medical X-ray Collimator Manual X-RAY BEAM TREITER SR202

I-Medical X-ray Collimator Manual X-RAY BEAM TREITER SR202

I-Medical X-ray Collimator Manual X-RAY BEAM TREITER SR202

Incazelo emfushane:

Izici
Ihambelana nemishini yokuxilonga ye-X-ray usebenzisa i-150kv tube voltage, kufaka phakathi izinhlelo zedijithali ze-DR kanye nezinhlelo ezijwayelekile
 Insimu ye-X-ray irradiation field iyisikwele
Conform kumazinga afanele kazwelonke nemboni
Usayizi we-Small
Ukwethembeka igh kanye nokusebenza kwezindleko eziphakeme
Isebenzisa ungqimba olulodwa, amasethi amabili amaqabunga aholayo kanye nomklamo okhethekile wokuvikela wangaphakathi ukuvimba ama-x-ray.
Ukulungiswa kwenkambu yokungenisa i-inradiation kuyinto yezandla, kuyashintshwa ngokuqhubekayo
Inkambu ebonakalayo ebonakalayo yamukela ama-LED bulbs
 Ukulibala kwesiko lokubambezeleka okwakhelwe ngaphakathi kuvala isibani ngemizuzwana engama-30 ngemuva kokusebenza, kanye nenketho yezandla ukucisha ukukhanya ngesikhathi sokusebenza kuyatholakala. Lezi zici zenzelwe ukwelula impilo ye-bulb futhi zinciphise ukusetshenziswa kwamandla.


Imininingwane Yomkhiqizo

Izinkokhelo nezinqubo zokuthumela:

Amathegi Omkhiqizo

Amapharamitha aphambili wezobuchwepheshe nezinkomba

I-x-ray ukuvuza: <1mgy / h (150kv, 4mA)
Ibanga leLothi lingashintshwa ngokuya nge-X-ray tube ethile esetshenzisiwe. Ibanga elijwayelekile lingu-60mm kusuka ekugxileni kwe-X-ray tube endaweni ekhuphukayo ye-Beam Limiter.
Insimu ye-Irradiation ye-Memadimum: 43cmx43cm (Sid = 1m)
Insimu ye-Irradiation ye-Irradiation: <5cmx5cm (sid = 1m)
 Ukukhanya kwensimu yokukhanya okubonakalayo:> 140LUX (Sid = 1m)
Light field ismonity: <2% @ sid
Ukuhlunga kwe-Inlinent: 1mmal / 75kv
Ukufakwa kwe-Power: I-24VAC / 50W noma i-24VDC / 50W
Ubukhulu: 185mm × 198mm × 145mm (ubude × ububanzi × ukuphakama)
weight: 6.2kg

Ongakukhetha:
Isihlungi esingeziwe esingeziwe
I-Special Electrical interface
I-Interface ye-Special Tube Ibhola
one izwi line Laser locator

Amapharamitha Ezobuchwepheshe

I-MAX Voltage

I-150kv

Ubukhulu be-X-ray

440mm × 440mm (sid = 100cm)

Ukukhanya okumaphakathi kwensimu yokukhanya

> 160 lux

Isilinganiso se-Edge Contrast

> 4: 1

Isidingo Sokunikezela Amandla we-Projection Lamp

24v / 150w

Isikhathi sesikhathi se-Bright X-ray ubude

30s

Ibanga kusuka endaweni egxile kwi-X-ray tube kuya entabeni yeNtaba ye-Collimator Sid (MM) (Ngokuzithandela)

60

Ukuhlunga (okungokwemvelo) 75kv

1mmal

I-FILTRATION (eyengeziwe)

Ongaphandle ongakukhetha

Indlela yokulawula

Umsebenzi wezandla

Shayela imoto

--

Ukulawulwa Kwemoto

--

Ukutholwa kwesikhundla

--

Amandla okufaka

I-AC24V

(Sid)

Ukucushwa Okujwayelekile

Imiyalo ye-Laser Yesikhungo

-nokukhetha ngokuthanda

Ubukhulu (mm) (w × l × h)

185 × 198 × 145

Isisindo (kg)

6.8

Izinja

Le x-ray collimator ilungele i-voltage voltage 150kv, uDkt Digital digital kanye nemishini yokuxilonga ye-X-ray.


  • Okwedlule:
  • Olandelayo:

  • Ubuncane be-oda le-oda: 1pc

    Intengo: Ukuxoxisana

    Imininingwane yokupakisha: I-100pcs ye-carton ngayinye noma eyenziwe ngokwezifiso ngokuya ngobungako

    Isikhathi sokulethwa: 1 ~ 2 amasonto ngokusho kwenani

    Imibandela Yokukhokha: I-100% T / T kusengaphambili noma i-Western Union

    Ikhono lokuhlinzeka: 1000pcs / ngenyanga

    Bhala umyalezo wakho lapha bese usithumela kithi