I-China Medical X-ray Collimator I-X-ray Collimator SR301 Umkhiqizi Nomhlinzeki | I-Sailray
I-Medical X-ray Collimator Automatic X-ray Collimator SR301

I-Medical X-ray Collimator Automatic X-ray Collimator SR301

I-Medical X-ray Collimator Automatic X-ray Collimator SR301

Incazelo emfushane:

Izici
Ifanele i-tube voltage 150kV, i-DR digital kanye nemishini yokuxilonga ye-X-ray evamile
 Inkundla yokuthela ngemisebe ye-X-ray inonxande
Ukuhambisana namazinga afanele kazwelonke nawemboni
Ukuthembeka okuphezulu nokusebenza kwezindleko eziphezulu
 Izendlalelo ezikabili kanye namasethi amabili amaqabunga omthofu kanye nesakhiwo esikhethekile sokuzivikela sangaphakathi sisetshenziselwa ukuvikela ama-X-ray. Amaqabunga omthofu aphezulu angangena efasiteleni leshubhu le-X-ray, elingavikela imisebe ehlakazekile elahlekile ngokuphumelelayo.
Ukulungiswa kwenkundla yokuthela imisebe kwenziwa ngesandla, kuyalungiseka ngokuqhubekayo
Inkambu yokukhanya ebonakalayo isebenzisa ama-LED ama-bulbs akhanya kakhulu
Isekhethi yokulibaziseka yangaphakathi ingacisha isibani ngokuzenzakalela ngemva kwamasekhondi angu-30 okukhanya, futhi ingacisha isibani mathupha phakathi nesikhathi sokukhanya ukuze kwelule impilo yesibani futhi yonge amandla.
Uxhumano lwemishini olulula futhi oluthembekile nge-X-ray tube, kulula ukulungisa


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Imingcele yezobuchwepheshe eyinhloko nezinkomba

Ukuvuza kwe-X-ray: <1mGy/h (150kV, 4mA)
Ibanga elisuka lapho kugxilwe khona ishubhu ye-X-ray ukuya endaweni yokufaka isikhawulo se-beam: 60mm (ingalungiswa ngokuvumelana namashubhu ahlukene)
Isikali senkambu yokuthela imisebe: 48cmX48cm (SID=1m)
Indawo encane yokuthela imisebe: <5cmX5cm (SID=1m)
 Ukukhanya kwenkambu yokukhanya okubonakalayo: >140lux (SID=1m)
Ukuvumelana kwenkambu yokukhanya: <2%@SID
Ukuhlunga okungokwemvelo: 1mmAl/75kV
Amandla okokufaka: 24VAC/50W noma 24VDC/2A
 Ubukhulu: 200mm×230mm×170mm (ubude×ububanzi×ubude)
Isisindo: 8.4kg

Ongakukhetha:
Isihlungi esengeziwe sangaphandle
Isixhumi esibonakalayo sikagesi esikhethekile
Isixhumi esibonakalayo sebhola leshubhu
I-laser locator yegama elilodwa (Ikilasi 1)

Imingcele yezobuchwepheshe

I-Max Voltage

150KV

Ibanga eliphezulu lenkambu ye-X-ray

480mm×480mm (SID=100cm)

Ukukhanya okumaphakathi kwenkambu yokukhanya

> 160 lux

Isilinganiso sokungafani somphetho

> 4:1

Isidingo sokuphakelwa kwamandla kwesibani sokuqagela

24V AC/150W

Ubude benkambu ye-X-ray ekhanyayo Kanye

30S

Ibanga ukusuka ku-Focal Spot yeshubhu le-X-ray ukuya endizeni yokukhweza ye-collimator SID (mm)(kuyakhetheka)

60

Ukuhlunga(Imvelo) 75kV

1 mml

Ukuhlunga(Okwengeziwe)

Ongakukhetha kwangaphandle

Indlela yokulawula

Imanuwali

Shayela injini

--

Ukulawulwa Kwezimoto

--

Ukutholwa kwesikhundla

--

Amandla okokufaka

I-AC24V

(SID)Itheyiphu yokulinganisa

Ukucushwa Okujwayelekile

Imiyalo ye-laser ephakathi

ngokuzikhethela

Ubukhulu(mm)(W×L×H)

200×230×170

Isisindo(Kg)

8.4

Izinhlelo zokusebenza

Le collimator ilungele amashubhu kagesi angu-150kV, i-DR digital kanye nemishini evamile yokuhlola i-X-ray


  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umyalezo wakho lapha futhi usithumelele wona