I-China Medical X-ray Collimator Manual X-ray beam limitter SR302 Umkhiqizi Nomphakeli | I-Sailray
I-Medical X-ray Collimator Manual X-ray beam limitter SR302

I-Medical X-ray Collimator Manual X-ray beam limitter SR302

I-Medical X-ray Collimator Manual X-ray beam limitter SR302

Incazelo emfushane:

Ifanele izinto ezijwayelekile zokuxilonga ze-X-ray ezinamashubhu kagesi angu-150kV
 Inkundla yokuthela ngemisebe ye-X-ray inonxande
Ukuhambisana namazinga afanele kazwelonke nawemboni
Usayizi omncane
Ukuthembeka okuphezulu nokusebenza kwezindleko eziphezulu
 Ukusebenzisa izendlalelo ezimbili namasethi amabili amaqabunga omthofu kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela ama-X-ray
Ukulungiswa kwendawo yokuthela kwenziwa ngesandla, futhi inkambu yokuthela imisebe ihlale ilungiseka.
Inkambu yokukhanya ebonakalayo isebenzisa ama-LED ama-bulbs akhanya kakhulu
Isekhethi yokulibaziseka yangaphakathi ingacisha isibani ngokuzenzakalela ngemva kwamasekhondi angu-30 okukhanya, futhi ingacisha isibani mathupha phakathi nesikhathi sokukhanya ukuze kwelule impilo yesibani futhi yonge amandla.
Uxhumano lwemishini olulula futhi oluthembekile nge-X-ray tube, kulula ukulungisa


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Imingcele yezobuchwepheshe

I-Max Voltage

150KV

Ibanga eliphezulu lenkambu ye-X-ray

480mm×480mm (SID=100cm)

Ukukhanya okumaphakathi kwenkambu yokukhanya

> 160 lux

Isilinganiso sokungafani somphetho

> 4:1

Isidingo sokuphakelwa kwamandla kwesibani sokuqagela

24V AC/150W

Ubude benkambu ye-X-ray ekhanyayo Kanye

30S

Ibanga ukusuka ku-Focal Spot yeshubhu le-X-ray ukuya endizeni yokukhweza ye-collimator SID (mm)(kuyakhetheka)

60

Ukuhlunga(Imvelo) 75kV

1 mml

Ukuhlunga(Okwengeziwe)

Khetha mathupha ukuhlunga okuthathu

Indlela yokulawula

Imanuwali

Shayela injini

--

Ukulawulwa Kwezimoto

--

Ukutholwa kwesikhundla

--

Amandla okokufaka

I-AC24V

(SID)Itheyiphu yokulinganisa

Ukucushwa Okujwayelekile

Imiyalo ye-laser ephakathi

ngokuzikhethela

Ubukhulu(mm)(W×L×H)

260×210×190

Isisindo(Kg)

7.9

Izinhlelo zokusebenza

Le collimator ye-x-ray iyasebenza ezintweni ezijwayelekile zokuxilonga ze-X-ray ezinamashubhu kagesi angu-150kV.

Qaphela

Uma ushintsha, ungathinti ngokuqondile ikesi lengilazi yesibani ngezandla zakho ukuvimbela ingilazi
icala lokungcoliswa izigxivizo zeminwe nokungcola okunamafutha. Ngemva kokushintsha, sicela usule ikesi lengilazi lika
isibani esinotshwala ukususa amabala.
Ngemuva kokusetshenziswa kwe-beam limiter, ingaphezulu lendlu kufanele lisulwe nge-solvent ye-inorganic
njalo ezinyangeni ezintathu ukuze ihlale ihlanzekile.
Sicela ulahle udoti walo mkhiqizo ngokuhambisana nemithetho efanele yokuvikela imvelo
kanye nemithethonqubo kahulumeni wasekhaya ukuze kuvikelwe imvelo yendawo.

  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umyalezo wakho lapha futhi usithumelele wona