I-China Medical X-ray collimator Okuzenzakalelayo kwe-x-ray RF202 Umkhiqizi Nomphakeli |I-Sailray
I-Medical X-ray collimator Automatic x-ray collimator RF202

I-Medical X-ray collimator Automatic x-ray collimator RF202

I-Medical X-ray collimator Automatic x-ray collimator RF202

Incazelo emfushane:

Izici
Ifanele i-tube voltage 150kV, i-DR digital kanye nemishini yokuxilonga ye-X-ray evamile
 Inkundla yokuthela ngemisebe ye-X-ray inonxande
Ukuhambisana namazinga afanele kazwelonke nawemboni
Ukuthembeka okuphezulu nokusebenza kwezindleko eziphezulu
 Ukusebenzisa ungqimba olulodwa namasethi amabili amaqabunga omthofu kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela ama-X-ray
Ukulungiswa kwensimu ye-irradiation kugesi, ukunyakaza kweqabunga lomthofu kuqhutshwa yi-motor stepping, futhi inkambu yokukhanyisa ihlale ilungiswa.
 Lawula i-beam limiter ngokusebenzisa ukuxhumana kwebhasi ye-CAN noma ukushintshwa kwezinga, noma ulawule ngesandla isikhawuli se-beam esiphambi kwakho, futhi isikrini se-LCD sibonisa isimo nemingcele ye-beam limiter.
Inkambu yokukhanya ebonakalayo yamukela ama-LED ama-bulb anokukhanya okuphezulu
Isekhethi yokulibaziseka yangaphakathi ingacisha isibani ngokuzenzakalela ngemva kwamasekhondi angu-30 okukhanya, futhi ingacisha isibani mathupha phakathi nesikhathi sokukhanya ukuze kwelule impilo yesibani futhi yonge amandla.
Uxhumano lwemishini olulula futhi oluthembekile nge-X-ray tube, kulula ukulungisa


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Imingcele yezobuchwepheshe

I-Max Voltage 150KV
Ibanga eliphezulu lenkambu ye-X-ray 430mm×430mm (SID=100cm)
Ukukhanya okumaphakathi kwenkambu yokukhanya > 160 lux
Isilinganiso sokungafani somphetho > 4:1
Isidingo sokuphakelwa kwamandla kwesibani sokuqagela 24V AC/150W
Ubude benkambu ye-X-ray ekhanyayo Kanye 30S
Ibanga ukusuka ku-Focal Spot yeshubhu le-X-ray ukuya endizeni yokukhweza ye-collimator SID (mm)(kuyakhetheka) 60
Ukuhlunga(Imvelo) 75kV 1 mml
Ukuhlunga(Okwengeziwe) Ongakukhetha kwangaphandle
Indlela yokulawula Ugesi/ Manual
Shayela injini I-Stepper Motor
Ukulawulwa Kwezimoto Izimpawu ze-TTL Level
Ukutholwa kwesikhundla I-Potentiometer
Amandla okokufaka I-AC24V/DC24V
(SID)Itheyiphu yokulinganisa ngokuzikhethela
Imiyalo ye-laser ephakathi ngokuzikhethela
Ubukhulu(mm)(W×L×H) 185×230×145
Isisindo(Kg) 7.2

Imingcele yezobuchwepheshe eyinhloko nezinkomba

Ukuvuza kwe-X-ray: <1mGy/h (150kV, 4mA)
Ibanga elisuka lapho kugxilwe khona ishubhu ye-X-ray ukuya endaweni yokufaka isikhawulo se-beam: 60mm (ingalungiswa ngokuvumelana namashubhu ahlukene)
Isikali senkambu yokuthela imisebe: 43cmX43cm (SID=1m)
Indawo encane yokuthela imisebe: <5cmX5cm (SID=1m)
 Ukukhanya kwenkambu yokukhanya okubonakalayo: >140lux (SID=1m)
Ukuvumelana kwenkambu yokukhanya: <2%@SID
Ukuhlunga okungokwemvelo: 1mmAl/75kV
 Okokufaka kwamandla enkambu yokukhanya: 24VAC/50W noma DC24V/1A
 Ukufakwa kwamandla okulawula ugesi: 24VDC/2A
Iphrothokholi yebhasi ye-CAN: CAN2.0A
 Ubukhulu: 186mm×230mm×145mm (ubude×ububanzi×ubude)
Isisindo: 7.2kg

Ongakukhetha:
Isihlungi esengeziwe sangaphandle
Isixhumi esibonakalayo sikagesi esikhethekile
Isixhumi esibonakalayo sebhola leshubhu

Izinhlelo zokusebenza

Le collimator ye-x-ray ilungele amashubhu kagesi angu-150kV, i-DR digital kanye nemishini yokuxilonga ye-X-ray evamile


  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umlayezo wakho lapha futhi usithumelele wona