Leli shubhu lidizayinelwe ukumiselela iyunithi ye-x-ray ye-TOSHIBA D-051 paranoiac yamazinyo futhi itholakalela amandla kagesi weshubhu elizilungisayo noma isekethe ye-DC.
Umthamo ophezulu wokugcina ukushisa kwe-anode uqinisekisa ububanzi bezinhlelo zokusebenza zokufakwa kwamazinyo ngaphakathi emlonyeni. I-anode eklanywe ngokukhethekile inika amandla izinga eliphezulu lokulahla ukushisa eliholela ekusebenzeni okuphezulu kwesiguli kanye nempilo ende yomkhiqizo. Isivuno esiqhubekayo somthamo omkhulu phakathi nayo yonke impilo yeshubhu siqinisekiswa yithagethi ye-tungsten ephakeme kakhulu. Ukulula kokuhlanganiswa emikhiqizweni yesistimu kwenziwa lula ukwesekwa kwezobuchwepheshe.
Leli shubhu lenzelwe ukumiselela i-TOSHIBA D-051 paranoiaciyunithi ye-x-ray yamazinyofuthi itholakalela amandla kagesi weshubhu ngokuzilungisela yona noma ngesekethe ye-DC.
I-Nominal Tube Voltage | 100kV |
I-Nominal Inverse Voltage | 115kV |
Amandla Okufaka Amagama (ku-1.0s) | ukuzilungisa: 840W DC: 1750W |
Ubukhulu. I-Anode Cooling Rate | 265W |
Ubukhulu. Okuqukethwe Kokushisa kwe-Anode | 30kj |
Izici ze-Filament | Ifmax3.5A,5.5±0.5V |
I-Nominal Focal Spot | 0.5 (IEC60336/2005) |
I-Engeli eqondiwe | 5° |
Okuqondisiwe | I-Tungsten |
Uhlobo lwe-Cathode | I-W filament |
Ukuhlunga Okuphakade | Okuncane. 0.5mmAl/50 kV(IEC60522/1999) |
Ubukhulu | 145mm ubude by 50mm ububanzi |
Isisindo | Cishe.480 amagremu |
Ukugcina uhlelo lwesinongo
Ngaphambi kokusetshenziswa, gcoba ishubhu ngokuhambisana neshejuli yesinongo enikezwe ngezansi kuze kube
i-tube voltage edingekayo ifinyelelwa. Isibonelo esinikeziwe - sidinga ukubuyekezwa ngumenzi
futhi kucaciswe eshidini ledatha lengxenye:
Uhlelo lokuqala lwesinongo olungenayo kanye nesinongo sesikhathi sokungenzi lutho (ngaphezu kwezinyanga eziyi-6)
Isifunda: DC (Isekelwe maphakathi)
Lapho i-tube current ingazinzile ku-seasoning, vala ngokushesha i-tube voltage kanye
ngemva kwesikhawu semizuzu emi-5 noma ngaphezulu, khulisa i-voltage yeshubhu kancane kancane ukusuka kokuphansi
I-voltage ngenkathi uqinisekisa ukuthi i-tube current izinzile.
Ukusebenza kwe-voltage okumelana neyunithi yeshubhu kuzokwehliswa njengesikhathi sokuchayeka kanye
inani lokusebenza liyakhula. Ukulandela umthelela okufana nebala kungase kuvele kushubhu ye-x-ray
indawo okuhloswe ngayo ngokuphuma kancane phakathi nesinongo. Lezi zenzakalo zikodwa
inqubo yokubuyisela ukusebenza kwe-voltage emile ngaleso sikhathi.
Ngakho-ke, uma isebenza ngokuzinzile ku-voltage ephezulu yeshubhu yesithokelo esilandelayo
kubo, i-tube unit ingasetshenziswa ngaphandle kokuphazamiseka ekusebenzeni kwayo kagesi
ezisetshenziswayo
Umthamo wokugcina ukushisa kwe-anode nokupholisa
Isivuno somthamo ophezulu njalo
Ukuphila okuhle kakhulu
Inani elincane le-oda: 1pc
Inani: Ukuxoxisana
Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani
Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani
Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION
Supply Amandla: 1000pcs/ ngenyanga