I-China Panoramic Dental X-ray Tube TOSHIBA D-051 Umkhiqizi Nomhlinzeki |I-Sailray
I-Panoramic Dental X-ray Tube TOSHIBA D-051

I-Panoramic Dental X-ray Tube TOSHIBA D-051

I-Panoramic Dental X-ray Tube TOSHIBA D-051

Incazelo emfushane:

Uhlobo: Ishubhu ye-anode emile ye-x-ray
Isicelo: Okweyunithi ye-x-ray yamazinyo panoramic
Imodeli: KL5A-0.5-105
Ilingana ne-TOSHIBA D-051
Ishubhu yengilazi yekhwalithi ephezulu ehlanganisiwe


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Incazelo

Leli shubhu lidizayinelwe ukumiselela iyunithi ye-X-ray ye-TOSHIBA D-051 paranoiac yamazinyo futhi itholakalela amandla kagesi eshubhu enezilungiselo ezizilungisayo noma ze-DC.
Umthamo ophezulu wokugcina ukushisa kwe-anode uqinisekisa ububanzi bezinhlelo zokusebenza zokufakwa kwamazinyo ngaphakathi emlonyeni.I-anode eklanywe ngokukhethekile inika amandla izinga eliphezulu lokulahla ukushisa eliholela ekusebenzeni okuphezulu kwesiguli kanye nempilo ende yomkhiqizo.Isivuno esiqhubekayo somthamo omkhulu phakathi nayo yonke impilo yeshubhu siqinisekiswa yithagethi ye-tungsten ephakeme kakhulu.Ukulula kokuhlanganiswa emikhiqizweni yesistimu kwenziwa lula ukwesekwa kwezobuchwepheshe.

Izinhlelo zokusebenza

Leli shubhu lenzelwe ukumiselela i-TOSHIBA D-051 paranoiaciyunithi ye-x-ray yamazinyofuthi itholakalela amandla kagesi weshubhu ngokuzilungisela yona noma ngesekethe ye-DC.

Idatha yobuchwepheshe

I-Nominal Tube Voltage 100kV
I-Nominal Inverse Voltage 115kV
Amandla Okufaka Amagama (ku-1.0s) ukuzilungisa: 840W DC: 1750W
Ubukhulu.I-Anode Cooling Rate 265W
Ubukhulu.Okuqukethwe Kokushisa kwe-Anode 30kj
Izici ze-Filament Ifmax3.5A,5.5±0.5V
I-Nominal Focal Spot 0.5 (IEC60336/2005)
I-Engeli eqondiwe
Okuqondisiwe I-Tungsten
Uhlobo lwe-Cathode I-W filament
Ukuhlunga Okuphakade Okuncane.0.5mmAl/50 kV(IEC60522/1999)
Ubukhulu 145mm ubude by 50mm ububanzi
Isisindo Cishe.480 amagremu

Izithombe ezinemininingwane

I-KL5A-0.5-105

Ukugcina uhlelo lwesinongo
Ngaphambi kokusetshenziswa, gcoba ishubhu ngokuhambisana neshejuli yesinongo enikezwe ngezansi kuze kube
i-tube voltage edingekayo ifinyelelwa.Isibonelo esinikeziwe - sidinga ukubuyekezwa ngumenzi
futhi kucaciswe eshidini ledatha lengxenye:
Uhlelo lokuqala lwesinongo olungenayo kanye nesinongo sesikhathi sokungenzi lutho (ngaphezu kwezinyanga eziyi-6)
Isifunda: DC (Isekelwe maphakathi)

I-KL5A 老练图
Lapho i-tube current ingazinzile ku-seasoning, vala ngokushesha i-tube voltage kanye
ngemva kwesikhawu semizuzu emi-5 noma ngaphezulu, khulisa i-voltage yeshubhu kancane kancane ukusuka kokuphansi
I-voltage ngenkathi uqinisekisa ukuthi i-tube current izinzile.
Ukusebenza kwe-voltage okumelana neyunithi yeshubhu kuzokwehliswa njengesikhathi sokuchayeka kanye
inani lokusebenza liyakhula.Ukulandela umthelela okufana nebala kungase kuvele kushubhu ye-x-ray
indawo okuhloswe ngayo ngokuphuma kancane phakathi nesinongo.Lezi zenzakalo zikodwa
inqubo yokubuyisela ukusebenza kwe-voltage emile ngaleso sikhathi.
Ngakho-ke, uma isebenza ngokuzinzile ku-voltage ephezulu yeshubhu yesithokelo esilandelayo
kubo, i-tube unit ingasetshenziswa ngaphandle kokuphazamiseka ekusebenzeni kwayo kagesi
ezisetshenziswayo

Inzuzo Yokuncintisana

Umthamo wokugcina ukushisa kwe-anode nokupholisa
Isivuno somthamo ophezulu njalo
Ukuphila okuhle kakhulu


  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umlayezo wakho lapha futhi usithumelele wona

    imikhiqizo ehlobene