Lo mkhiqizo wenziwe futhi wathuthukiswa ngokuvumelana nemithetho elandelayo, iziqondiso kanye nemithetho yokuklama:
◆ Umhlahlandlela woMkhandlu 93/42 / EEC mhlaka 14 Juni 1993 maqondana namadivayisi wezokwelapha(UkumakaIsihlehlukene.
◆ En Iso 13485: 2016 Izinhlelo zokulawulwa kwekhwalithi yezokwelapha - Izidingo zokulawula
izinhloso..
◆ En iso 14971: Amadivayisi we-2012Medical - Ukusetshenziswa kokulawulwa kwengozi kumadivayisi wezokwelapha (ISO 14971: 2007, inguqulo elungisiwe 2007-10-01)
◆ I-ESS15223-1: Amadivayisi we-2012Medical - Izimpawu ezisetshenziswa ngamalebula wedivayisi yezokwelapha, ilebula kanye nemininingwane okufanele ihlinzekwe Ingxenye 1: Izidingo ezijwayelekile
+:IKhomishini Yezizwe Zama-Electrotechnical (IEC), amazinga alandelayo abhekwa ikakhulukazi.
Inkomba ejwayelekile | Izihloko |
En 60601-2-54: 2009 | Imishini kagesi yezokwelapha - Ingxenye 2-54: Izidingo ezithile zokuphepha eziyisisekelo nokusebenza okubalulekile kwemishini ye-X-ray ye-radiography ne-radioscopy |
IEC60526 | I-plug ephezulu ye-voltage ikhebula nokuxhumana kwesokhethi kwemishini ye-X-ray |
IEC 60522: 1999 | Ukuzimisela kokuhlunga okungapheli kweminyaka emikhulu ye-X-ray tube |
IEC 60613-2010 | Izici zikagesi, ezishisayo nezilayishwayo zokujikeleza kwamashubhu we-anode X-ray ajikelezayo ekuhlolweni kwezokwelapha |
IEC60601-1: 2006 | Imishini kagesi yezokwelapha - Ingxenye 1: Izidingo ezijwayelekile zokuphepha eziyisisekelo nokusebenza okubalulekile |
IEC 60601-1-3: 2008 | Imishini kagesi yezokwelapha - Ingxenye 1-3: Izidingo ezijwayelekile zokuphepha eziyisisekelo nokusebenza okubalulekile - Okujwayelekile Kokubumbana |
IEC60601-2-28: 2010 | Imishini kagesi yezokwelapha - Ingxenye 2-28: Izidingo ezithile zokuphepha eziyisisekelo nokusebenza okubalulekile kwemihlangano ye-X-ray tube yokuxilongwa kwezokwelapha |
IEC 60336-2005 | Imihlangano kagesi kagesi kagesi-x-ray tube yemihlangano yokuxilongwa kwezokwelapha - izici zezindawo ezigxile |
● Ukuqokwa kuhlanganiswa kanjena:
Mwhx7I-360 | Ithumbu | A | Isokhethi eliphakeme le-voltage elinenkomba engu-90 degree |
I-MWTX73-0.6/1.2-1I-50H | B | Isokhethi eliphakeme le-voltage elinenkomba engama-270 degree |
Impahla | Ukucacisa | -Vamile | |
Amandla okufaka wokufaka we-anode | F 1 | F 2 | IEC 60613 |
20kw (50 / 60hz) 30kw (150 / 180hzz | I-50kW (50 / 60hz) I-74kw (150 / 180hz) | ||
Umthamo wokugcina ukushisa | 212 KJ (300KHU) | IEC 60613 | |
Amandla amakhulu okupholisa we-anode | I-750w | ||
Umthamo wokugcina ukushisa | I-900kj | ||
UMax. Ukuhlanzeka okuqhubekayo kokushisa ngaphandle kwe-Air-Ciwuna | I-180w | ||
Impahla ye-anodeI-anode top coating impahla | I-Rhenium-Tungsten-TzM (RTM) Rhenium-Tungsten- (Rt) | ||
I-Target Angle (Ref: I-Axis Reference Exis) | 12 ° | IEC 60788 | |
I-X-RAY TUBE CHALSE I-FILTRATION | 1.5 mm al / 75kv | IEC 60601-1-3 | |
Inani lezindawo eziphakeme | F1 (ukugxila okuncane) | F2 (ukugxila okukhulu) | IEC 60336 |
0.6 | 1.2 | ||
I-X-RAY TUBE TUBE THE VOLTAGEI-radiographicI-FluoRoscopic | I-150kv I-125kv | IEC 60613 | |
Idatha eCathode Heating UMax. -dlulayo I-MAX Voltage | ≈ / ac, <20 khz | ||
F1 | F 2 | ||
5.4a ≈9V | 5.4 a ≈17V | ||
Imisebe yokuvuza ku-150 kV / 3MA ebangeni elingu-1m | ≤1.0mgy / h | IEC60601-1-3 | |
Inkambu ye-radiation ephezulu |
I-430 × 430mm e-SID 1M | ||
Isisindo somhlangano we-X-ray Tube | Approx. 18 kg |
Ubungcele | Imikhawulo yokusebenza | Ukuhamba nokugcina imikhawulo |
Izinga lokushisa elikhona | Kusuka ku-10℃kuya ku-40℃ | Kusuka- 20℃to 70℃ |
Umswakama ohlobene | ≤75% | ≤93% |
Ingcindezi ye-barometric | Kusuka ku-70kpa kuya ku-106kpa | Kusuka ku-70kpa kuya ku-106kpa |
Isitaki esi-1 sesigaba
Iphuzu lokuhlola | C-M | C-A |
Ukumelana Nezinsuku | ≈18.0 ... 22.0ωωω | ≈45.0 ... 55.0ωω |
I-MAX.Perssupess Operating Voltage (Run-up) | I-230V ± 10% | |
Ncoma i-voltage esebenzayo (Run-up) | I-160V ± 10% | |
I-Braking Votage | I-70VDC | |
Run-on voltage ekuvezeni | Ama-80VRMS | |
Run-on vororoscopy | I-20V-40VRMS | |
Isikhathi sokuqalisa (kuya ngohlelo lwe-Starter) | 1.2S |
Isexwayiso esibonakalayo nge-X-ray generator
1.Ukuqhuma kokuqhuma
Ungalokothi ufake ngaphezulu kwamandla alinganiselwe kwi-X-ray Tube Assembly
Uma amandla okufaka edlula ukucaciswa kwe-tube, kubangela izinga lokushisa elingaphezulu kwe-anode, faka i-tube ingilazi shatter bese ekugcineni izinkinga ezithethekile ngenxa yokukhiqiza umfutho we-oyela ngaphakathi komhlangano wezindlu ngaphakathi kwezezindlu.
Esimweni esibucayi kangako esibangela ukuqhekeka kwezindlu ngomthwalo ngaphezulu komthwalo, ukushintshwa kwe-thermal yokuphepha akukwazi ukuvikela i-X-ray tube noma ngabe iyasebenza
*KileIzingxenye zokubopha izindlu zokuvalwa kwezindlu.
*KileUkulimala kwabantu kubandakanya nokushiswa ngenxa yokuphunyuka kwamafutha ashisayo.
*KileIngozi yomlilo ngenxa yethagethi ye-anode evuthayo.
I-x- ray generator kufanele ibe nomsebenzi wokuvikela olawula amandla okufaka ukuba ngaphansi kokucaciswa kwe-tube.
I-2.electric Shock
Ukugwema ubungozi bokushaqeka kukagesi, le mishini kufanele ixhumeke kuphela ekuhlinzekweni okuvikela umhlaba ovikelayo.
3.Nga ukuguqulwa kwalolu hlelo kuvunyelwe !!
Ukuqapha ku-interface nge-X-ray generator
Isilinganiso se-1.Over
Umhlangano we-X-ray Tube ungaphulwa ngokufaka isicelo esisodwa nje sokudubula.
Sicela ufunde amashidi wesikhathi sobuchwepheshe ngokucophelela bese ulandela imiyalo.
2.Ukuhlunga okungapheli
TUgcwele ukugcwala kanye nebanga phakathi kwe-X-ray pockal spot kanye nomzimba womuntu kulawulwa ngokusemthethweni.
TSawubona kufanele ahambisane nomthethonqubo.
3.Shintsha ukuphepha okushisayo
I-X-RAY TUBE ASSEMBLY SOLDER I-THERMAL THERPAL SUPLAT SUFT Shintle ukwenqabela amanye amandla okufaka lapho izindlu zeshubhu zifinyelela emazingeni okushisa(80℃Isihlehlukeneye-switch-vula.
Ukushintsha akunconyelwe ukuxhuma ikhoyili ye-stator kuchungechunge umjikelezo.
Noma ngabe switch isebenza, ungalokothi uvule amandla ohlelo. Iyunithi elipholile kufanele lisebenze uma lisetshenziswa ngohlelo.
Ukungasebenzi kahle okulindelwe
I-X-RAY TUBE CHALDOL ingaba nengozi yokungasebenzi kahle ngenxa yokunqanyulwa kokuphila noma ukwehluleka.Uma izinkinga ezinkulu ezibangelwa ubungozi obungenhla bulindelwe, uyacelwa ukuba ube nohlelo oluphuthumayo lokugwema icala elinjalo.
Isicelo se-5.New
Uma usebenzisa umkhiqizo ngohlelo lokusebenza olusha kungabikwa kulolu mbono noma ngohlobo oluhlukile lwe-X-ray generator, sicela uxhumane nathi ngokuqinisekisa ukutholakala kwayo.
1 .x-ray radiationukuvikela
Lo mkhiqizo ugcwalisa izidingo ze-IEC 60601-1-3.
Lo mhlangano we-tube ye-X-ray Tube ukhipha imisebe ye-X-ray emisebeni ye-Operation.Only abaqeqeshiwe futhi abaqeqeshiwe bavunyelwe ukusebenzisa umhlangano we-X-ray Trucu.
Imiphumela efanelekile yomzimba ingadala ukulimala kwesiguli, ukukhiqizwa kwesistimu kufanele kuthathe isivikelo esifanele ukugwema imisebe ye-Ionization.
2.Dielectric 0l
I-X-RAY TUBE ASSEMBLY ine-dielectric 0il equkethe ukuqina kwamandla kagesi. Njengoba kunobuthi empilweni yomuntu,Uma kuvezwa endaweni engavinjelwe,Kufanele ilahlwe njengokulandela emthethweni wendawo.
3.
Umhlangano we-X-ray Tube awuvunyelwe ukusetshenziswa emoyeni kagesi ovuthayo noma owonakalisayo ·
4.Lungisa i-tube yamanje
Kuya ngezimo zokusebenza,Izici zeWilament zingashintshwa.
Lolu shintsho lungahle luqondiswe ekuchayweni kwesilinganiso se-X-ray tube.
Ukuvimbela umhlangano we-X-ray Trucu kusuka ekulimaleni,Lungisa ishubhu njalo njalo.
Ngaphandle lapho i-X-ray tube inenkinga yokuvutha alUkusetshenziswa kwesikhathi se-Ong,Ukulungiswa kwe-tube yamanje kuyadingeka.
5.X-ray tube lokushisa izindlu
Ungathinti e-X- ray Tube House Great ngemuva kokusebenza ngenxa yokushisa okuphezulu.
Hlala i-X-ray tube ukuze uphonswe.
6.
Ngaphambi kokusetshenziswa,Sicela uqinisekise isimo semvelo singaphakathi kokusebenza okusebenzayo.
7.Ahlonteke kahle
Ukuthintana kwe-P1ase kuya e-Sailray ngokushesha,Uma kukhona ukungasebenzi kahle komhlangano we-X-ray tube kuyaphawuleka.
I-8.Disposal
Umhlangano we-X-ray Tube kanye ne-tube aqukethe izinto ezifana namafutha nezinsimbi ezisindayo lapho imfucumfucu yezomthetho enobungani futhi efanelekile kufanelekile.
Sicela uxhumane nensizakalo yamakhasimende ngale nhloso.
Uma (a) indawo encane yokugxila
Uma (a) indawo enkulu yokugxila
Izici ezishisayo zezindlu
Srmwwx7360A
Hlunga umhlangano kanye nesigaba se-cross of port
I-TOROR Isixhumi se-Wiring
Ubuncane be-oda le-oda: 1pc
Intengo: Ukuxoxisana
Imininingwane yokupakisha: I-100pcs ye-carton ngayinye noma eyenziwe ngokwezifiso ngokuya ngobungako
Isikhathi sokulethwa: 1 ~ 2 amasonto ngokusho kwenani
Imibandela Yokukhokha: I-100% T / T kusengaphambili noma i-Western Union
Ikhono lokuhlinzeka: 1000pcs / ngenyanga