I-China X-RAY TUBE ILINGANA NO-TOSHIBA E7242 Umkhiqizi Nomhlinzeki | I-Sailray
I-X-RAY TUBE ILINGANA NO-TOSHIBA E7242

I-X-RAY TUBE ILINGANA NO-TOSHIBA E7242

I-X-RAY TUBE ILINGANA NO-TOSHIBA E7242

Incazelo emfushane:

Isicelo: X-ray tube umhlangano kuzo zonke izivivinyo zokuxilonga evamile nge ezivamile
noma iziteshi zokusebenzela ze-radiographic ne-fluoroscopic
◆Izici zokufaka : 12.5° Rhenium-Tungsten molybdenum target (RTM)
◆Izindawo okugxilwe kuzo: Ezincane 0.6, Ezinkulu: 1.2
◆ I-voltage yeshubhu ephezulu : 125kV
◆Ihlala nohlobo lwe-IEC60526 yezingxenye zekhebula lamandla kagesi aphezulu
◆Ijeneretha kagesi ephezulu kufanele ihambisane ne-IEC60601-2-7
◆ Ukuhlelwa kwe-IEC (IEC 60601-1:2005):IZIHLOKO ZESIGABA I ME

Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Isithenjwa Esijwayelekile

Isithenjwa Esijwayelekile

Izihloko

EN 60601-2-54:2009 Imishini kagesi yezokwelapha - Ingxenye 2-54: Izidingo ezikhethekile zokuphepha okuyisisekelo nokusebenza okubalulekile kwemishini ye-X-ray ye-radiography ne-radioscopy
I-IEC60526 Ipulaki yekhebula ene-voltage ephezulu kanye noxhumo lwesokhethi lwemishini ye-X-ray yezokwelapha
I-IEC 60522:1999 Ukunqunywa kokuhlunga okungapheli kwama-X-ray tube assemblies
I-IEC 60613-2010 Izici zikagesi, ezishisayo nezokulayisha zamashubhu e-X-ray e-anode azungezayo ukuze kuhlolwe udokotela
I-IEC60601-1:2006 Izinto zikagesi zezokwelapha - Ingxenye 1: Izidingo ezijwayelekile zokuphepha okuyisisekelo nokusebenza okubalulekile
I-IEC 60601-1-3:2008 Imishini kagesi yezokwelapha - Ingxenye 1-3: Izidingo ezijwayelekile zokuphepha okuyisisekelo nokusebenza okubalulekile - Izinga elihlanganisiwe: Ukuvikelwa kwemisebe kumshini wokuxilonga we-X-ray
I-IEC60601-2-28:2010 Imishini kagesi yezokwelapha - Ingxenye 2-28: Izidingo ezikhethekile zokuphepha okuyisisekelo nokusebenza okubalulekile kwamashubhu e-X-ray ukuze kuhlolwe udokotela
I-IEC 60336-2005 Imishini kagesi yezokwelapha-i-X-ray tube assemblies yokuxilongwa kwezokwelapha-Izici zezindawo okugxilwe kuzo

Incazelo

●Igama libhalwe kanje:

MWHX7110A

Ithubhu

A

Isokhethi ye-voltage ephezulu ene-90 degree direction

MWTX71-0.6/1.2-125

B

Isokhethi ye-voltage ephezulu ene-270 degree direction

Idatha Yezobuchwepheshe

Impahla

Ukucaciswa

Okujwayelekile

Amandla okufakwayo okuzenzela we-anode

F 1

F 2

I-IEC 60613

20kW(50/60Hz)

40kW(50/60Hz)

 

Umthamo wokugcina ukushisa kwe-anode

110 kJ ( 150kHU)

I-IEC 60613

Umthamo omkhulu wokupholisa we-anode

500W

 
Umthamo wokugcina ukushisa

900kJ

 
Ubukhulu. ukukhishwa kokushisa okuqhubekayo ngaphandle kwe-Air-circular

180W

 
Impahla ye-anodeI-anode top coating material

I-Rhenium-Tungsten-TZM(RTM)

I-Rhenium-Tungsten-(RT)

 
I-engeli eqondiwe (Ref: i-reference axis)

12.5 °

I-IEC 60788

X-ray tube ukuhlangana filtration inherent

1.5 mm Al / 75kV

I-IEC 60601-1-3

Indawo okugxilwe kuyo amanani okuzisholo

F1(ukugxila okuncane)

F2(ukugxila okukhulu)

I-IEC 60336

0.6

1.2

 
I-X-ray tube nominal voltageI-RadiographicI-Fluoroscopic

125kV

100kV

I-IEC 60613

Idatha ekushiseni kwe-cathode Ubukhulu. okwamanje

I-voltage enkulu

≈ /AC, <20 kHz

 

F1

F 2

 

5.1A

≈79V

5.1 A

≈1214 V

 
Ukuvuza kwemisebe ku-150 kV / 3mA ebangeni elingu-1m

0.5mGy/h

I-IEC60601-1-3

Inkundla yemisebe ephezulu

443×443mm ku-SID 1m

 
Isisindo somhlangano we-X-ray tube

Cishe. 18 kg

 

Imibandela yokusebenza, isitoreji kanye nezokuthutha

Imikhawulo

Imikhawulo yokusebenza

Imikhawulo yezokuthutha kanye nesitoreji

Izinga lokushisa le-ambient

Kusuka ku-10kuye 40

Kusuka ku-20to 70

Umswakama ohlobene

≤75%

≤93%

Ukucindezela kwe-Barometric

Ukusuka ku-70kPa kuye ku-106kPa

Ukusuka ku-70kPa kuye ku-106kPa

 

Amanani okhiye we-Stator

1-isigaba stator

Iphuzu lokuhlola

C-M

C-A

Ukumelana nokuqina

≈18.0…22.0Ω

≈45.0…55.0Ω

I-Max.permissible operating voltage(ukuqalisa)

230V±10%

Ncoma i-voltage yokusebenza (ukuqalisa)

160V±10%

I-voltage ye-Braking

70VDC

I-voltage esebenzayo ekuchayekeni

80vm

I-voltage esebenzayo ku-fluoroscopy

20V-40Vrms

Isikhathi sokuqalisa (kuye ngesistimu yokuqalisa)

1.2s

Isexwayiso Ekusebenzeni

1 .I-X-ray Radiationisivikelo

Lo mkhiqizo ufeza izidingo ze-IEC 60601-1-3.

Lo mhlangano weshubhu le-X-ray ukhipha imisebe ye-X-ray ekusebenzeni.Ngakho yizisebenzi ezifanelekayo neziqeqeshiwe kuphela ezivunyelwe ukusebenzisa umhlangano weshubhu le-X-ray.

Imiphumela efanele ye-physiologic ingase ibangele ukulimala esigulini, ukukhiqizwa kwesistimu kufanele kuvikeleke okufanele ukugwema imisebe ye-ionization.

2.Dielectric 0il

I-X-ray tube assembly ine-dielectric 0il equkethwe ukuqina kwamandla kagesi aphezulu. Njengoba inobuthi empilweni yomuntu,uma ivezwe endaweni engavinjelwe,kufanele ilahlwe njengokulandelayo kumthethonqubo wendawo.

3 .Operation Atmosphere

Ukuhlanganiswa kweshubhu le-X-ray akuvunyelwe ukusetshenziswa emkhathini wegesi evuthayo noma ebolayo ·

4.Lungisa I-Tube Yamanje

Kuye ngezimo zokusebenza,izici ze-filament zingase zishintshwe.

Lolu shintsho lungase luhambisane nokuchayeka kwesilinganiso esiphezulu ekuhlanganisweni kweshubhu le-X-ray.

Ukuze uvimbele ukuhlanganiswa kweshubhu le-X-ray ukuthi lonakaliswe,lungisa i-tube current njalo.

Ngaphandle kwalokho lapho ithubhu ye-X-ray ine-arcing Inkinga ku-alukusetshenziswa isikhathi eside,ukulungiswa kwe-tube current kuyadingeka.

5.X-ray Tube Housing Temperature

Ungathinti indawo yezindlu ze-X-ray ngemva nje kokuhlinzwa ngenxa yokushisa okuphezulu.

Hlala i-X-ray tube ukuze upholiswe.

6.Imikhawulo yokusebenza

Ngaphambi kokusetshenziswa,sicela uqinisekise isimo sendawo ezungezile singaphakathi kweMigomo yokusebenza.

7.Noma yikuphi Ukungasebenzi

Sicela uthinte ku-SAILRAY ngokushesha,uma kukhona ukungasebenzi kahle kwe-X-ray tube assembly kuyabonwa.

8.Ukulahlwa

Ukuhlanganiswa kweshubhu ye-X-ray kanye neshubhu kuqukethe izinto ezifana nowoyela nezinsimbi ezisindayo okufanele kuqinisekiswe ukulahlwa kwazo okuhambisana nemvelo ngokuhambisana nemithetho kazwelonke esebenzayo. Ukulahlwa njengemfucuza yasekhaya noma yezimboni akuvunyelwe. Umkhiqizi unazo. ulwazi lobuchwepheshe oludingekayo futhi izothatha ishubhu ye-X-ray ibuyiselwe ukuze ilahlwe.

Sicela uxhumane nesevisi yamakhasimende ngale njongo.

Amajika wokukhishwa kwe-cathode

图片

Uma(A) Indawo Encane Egxilwe Ngayo

Ikhasi 1.2

If(A) Big Focal Spot

Ukulayisha okukodwa nochungechunge

Izimo:Tube Voltage Isigaba Sesithathu

I-Stator Power Frequency 50Hz/60Hz

Ngiyi)

图片4

T(ama)

Ngiyi)

图片3

T(ama)

Ukushisa nokupholisa ijika le-anode

  I-IEC60613

图片5

Ukushisa nokupholisa ijika lokuhlanganisa amashubhu e-X-ray

Izimpawu Zezindlu Ezishisayo

图片6

Imidwebo enobukhulu beshubhu ye-X-ray

I-SRMWHX7110A

图片7

I-Filter Assembly And Cross Section of Port

Isiqephu 27

I-Rotor Connector Wiring

Isiqephu 28

  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umyalezo wakho lapha futhi usithumelele wona