Isithenjwa Esijwayelekile | Izihloko |
EN 60601-2-54:2009 | Imishini kagesi yezokwelapha - Ingxenye 2-54: Izidingo ezikhethekile zokuphepha okuyisisekelo nokusebenza okubalulekile kwemishini ye-X-ray ye-radiography ne-radioscopy |
I-IEC60526 | Ipulaki yekhebula ene-voltage ephezulu kanye noxhumo lwesokhethi lwemishini ye-X-ray yezokwelapha |
I-IEC 60522:1999 | Ukunqunywa kokuhlunga okungapheli kwama-X-ray tube assemblies |
I-IEC 60613-2010 | Izici zikagesi, ezishisayo nezokulayisha zamashubhu e-X-ray e-anode azungezayo ukuze kuhlolwe udokotela |
I-IEC60601-1:2006 | Izinto zikagesi zezokwelapha - Ingxenye 1: Izidingo ezijwayelekile zokuphepha okuyisisekelo nokusebenza okubalulekile |
I-IEC 60601-1-3:2008 | Imishini kagesi yezokwelapha - Ingxenye 1-3: Izidingo ezijwayelekile zokuphepha okuyisisekelo nokusebenza okubalulekile - Izinga elihlanganisiwe: Ukuvikelwa kwemisebe kumshini wokuxilonga we-X-ray |
I-IEC60601-2-28:2010 | Imishini kagesi yezokwelapha - Ingxenye 2-28: Izidingo ezikhethekile zokuphepha okuyisisekelo nokusebenza okubalulekile kwamashubhu e-X-ray ukuze kuhlolwe udokotela |
I-IEC 60336-2005 | Imishini kagesi yezokwelapha-i-X-ray tube assemblies yokuxilongwa kwezokwelapha-Izici zezindawo okugxilwe kuzo |
●Igama libhalwe kanje:
MWHX7110A | Ithubhu | A | Isokhethi ye-voltage ephezulu ene-90 degree direction |
MWTX71-0.6/1.2-125 | B | Isokhethi ye-voltage ephezulu ene-270 degree direction |
Impahla | Ukucaciswa | Okujwayelekile | |
Amandla okufakwayo okuzenzela we-anode | F 1 | F 2 | I-IEC 60613 |
20kW(50/60Hz) | 40kW(50/60Hz) | ||
Umthamo wokugcina ukushisa kwe-anode | 110 kJ ( 150kHU) | I-IEC 60613 | |
Umthamo omkhulu wokupholisa we-anode | 500W | ||
Umthamo wokugcina ukushisa | 900kJ | ||
Ubukhulu. ukukhishwa kokushisa okuqhubekayo ngaphandle kwe-Air-circular | 180W | ||
Impahla ye-anodeI-anode top coating material | I-Rhenium-Tungsten-TZM(RTM) I-Rhenium-Tungsten-(RT) | ||
I-engeli eqondiwe (Ref: i-reference axis) | 12.5 ° | I-IEC 60788 | |
X-ray tube ukuhlangana filtration inherent | 1.5 mm Al / 75kV | I-IEC 60601-1-3 | |
Indawo okugxilwe kuyo amanani okuzisholo | F1(ukugxila okuncane) | F2(ukugxila okukhulu) | I-IEC 60336 |
0.6 | 1.2 | ||
I-X-ray tube nominal voltageI-RadiographicI-Fluoroscopic | 125kV 100kV | I-IEC 60613 | |
Idatha ekushiseni kwe-cathode Ubukhulu. okwamanje I-voltage enkulu | ≈ /AC, <20 kHz | ||
F1 | F 2 | ||
5.1A ≈7~9V | 5.1 A ≈12~14 V | ||
Ukuvuza kwemisebe ku-150 kV / 3mA ebangeni elingu-1m | ≤0.5mGy/h | I-IEC60601-1-3 | |
Inkundla yemisebe ephezulu | 443×443mm ku-SID 1m | ||
Isisindo somhlangano we-X-ray tube | Cishe. 18 kg |
Imikhawulo | Imikhawulo yokusebenza | Imikhawulo yezokuthutha kanye nesitoreji |
Izinga lokushisa le-ambient | Kusuka ku-10℃kuye 40℃ | Kusuka ku-20℃to 70℃ |
Umswakama ohlobene | ≤75% | ≤93% |
Ukucindezela kwe-Barometric | Ukusuka ku-70kPa kuye ku-106kPa | Ukusuka ku-70kPa kuye ku-106kPa |
1-isigaba stator
Iphuzu lokuhlola | C-M | C-A |
Ukumelana nokuqina | ≈18.0…22.0Ω | ≈45.0…55.0Ω |
I-Max.permissible operating voltage(ukuqalisa) | 230V±10% | |
Ncoma i-voltage yokusebenza (ukuqalisa) | 160V±10% | |
I-voltage ye-Braking | 70VDC | |
I-voltage esebenzayo ekuchayekeni | 80vm | |
I-voltage esebenzayo ku-fluoroscopy | 20V-40Vrms | |
Isikhathi sokuqalisa (kuye ngesistimu yokuqalisa) | 1.2s |
1 .I-X-ray Radiationisivikelo
Lo mkhiqizo ufeza izidingo ze-IEC 60601-1-3.
Lo mhlangano weshubhu le-X-ray ukhipha imisebe ye-X-ray ekusebenzeni.Ngakho yizisebenzi ezifanelekayo neziqeqeshiwe kuphela ezivunyelwe ukusebenzisa umhlangano weshubhu le-X-ray.
Imiphumela efanele ye-physiologic ingase ibangele ukulimala esigulini, ukukhiqizwa kwesistimu kufanele kuvikeleke okufanele ukugwema imisebe ye-ionization.
2.Dielectric 0il
I-X-ray tube assembly ine-dielectric 0il equkethwe ukuqina kwamandla kagesi aphezulu. Njengoba inobuthi empilweni yomuntu,uma ivezwe endaweni engavinjelwe,kufanele ilahlwe njengokulandelayo kumthethonqubo wendawo.
3 .Operation Atmosphere
Ukuhlanganiswa kweshubhu le-X-ray akuvunyelwe ukusetshenziswa emkhathini wegesi evuthayo noma ebolayo ·
4.Lungisa I-Tube Yamanje
Kuye ngezimo zokusebenza,izici ze-filament zingase zishintshwe.
Lolu shintsho lungase luhambisane nokuchayeka kwesilinganiso esiphezulu ekuhlanganisweni kweshubhu le-X-ray.
Ukuze uvimbele ukuhlanganiswa kweshubhu le-X-ray ukuthi lonakaliswe,lungisa i-tube current njalo.
Ngaphandle kwalokho lapho ithubhu ye-X-ray ine-arcing Inkinga ku-alukusetshenziswa isikhathi eside,ukulungiswa kwe-tube current kuyadingeka.
5.X-ray Tube Housing Temperature
Ungathinti indawo yezindlu ze-X-ray ngemva nje kokuhlinzwa ngenxa yokushisa okuphezulu.
Hlala i-X-ray tube ukuze upholiswe.
6.Imikhawulo yokusebenza
Ngaphambi kokusetshenziswa,sicela uqinisekise isimo sendawo ezungezile singaphakathi kweMigomo yokusebenza.
7.Noma yikuphi Ukungasebenzi
Sicela uthinte ku-SAILRAY ngokushesha,uma kukhona ukungasebenzi kahle kwe-X-ray tube assembly kuyabonwa.
8.Ukulahlwa
Ukuhlanganiswa kweshubhu ye-X-ray kanye neshubhu kuqukethe izinto ezifana nowoyela nezinsimbi ezisindayo okufanele kuqinisekiswe ukulahlwa kwazo okuhambisana nemvelo ngokuhambisana nemithetho kazwelonke esebenzayo. Ukulahlwa njengemfucuza yasekhaya noma yezimboni akuvunyelwe. Umkhiqizi unazo. ulwazi lobuchwepheshe oludingekayo futhi izothatha ishubhu ye-X-ray ibuyiselwe ukuze ilahlwe.
Sicela uxhumane nesevisi yamakhasimende ngale njongo.
Uma(A) Indawo Encane Egxilwe Ngayo
If(A) Big Focal Spot
Izimo:Tube Voltage Isigaba Sesithathu
I-Stator Power Frequency 50Hz/60Hz
Ngiyi)
T(ama)
Ngiyi)
T(ama)
I-IEC60613
Izimpawu Zezindlu Ezishisayo
I-SRMWHX7110A
I-Filter Assembly And Cross Section of Port
I-Rotor Connector Wiring
Inani elincane le-oda: 1pc
Inani: Ukuxoxisana
Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani
Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani
Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION
Supply Amandla: 1000pcs/ ngenyanga