I-China X-ray Tube Housing Assembly TOSHIBA E7239X Umkhiqizi Nomphakeli |I-Sailray
X-ray Tube Housing Assembly TOSHIBA E7239X

X-ray Tube Housing Assembly TOSHIBA E7239X

X-ray Tube Housing Assembly TOSHIBA E7239X

Incazelo emfushane:

◆ X-ray tube ukuhlanganiswa kwazo zonke izivivinyo zokuxilonga ngemishini evamile noma yedijithali yeradiographic kanye ne-fluoroscopic

◆Izici zokufaka : 16° ​​Rhenium-Tungsten molybdenum target (RTM)

◆Izindawo okugxilwe kuzo: Ezincane 1.0, Ezinkulu: 2.0

◆ I-voltage yeshubhu ephezulu :125kV

◆Ihlala nohlobo lwe-IEC60526 yezingxenye zekhebula lamandla kagesi aphezulu

◆Ijeneretha kagesi ephezulu kufanele ihambisane ne-IEC60601-2-7

Ukuhlukaniswa kwe-IEC (IEC 60601-1:2005):IZIHLOKO ZOKUSEBENZA I-IME


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Imithetho, izindinganiso kanye nemithethonqubo

Lo mkhiqizo wakhiwe futhi wathuthukiswa ngokuvumelana nemithetho elandelayo, iziqondiso kanye nemithethonqubo yokuklama:
◆ Isiqondiso soMkhandlu 93/42/EEC somhla ziyi-14 kuJuni 1993 mayelana nemishini yezokwelapha(Ukumakwa kwe-CE.
◆ I-TS EN ISO 13485:2016 Idivaysi yezokwelapha—Izinhlelo zokuphatha izinga—Izimfuneko zokulawula
izinjongo..
◆EN ISO 14971:2012Amadivayisi ezokwelapha - Ukusetshenziswa kokulawulwa kwezingcuphe kumadivayisi ezokwelapha (ISO 14971:2007, Inguqulo elungisiwe 2007-10-01)
◆ I-EN ISO15223-1:2012 Amadivayisi ezokwelapha——Izimpawu ezisetshenziswa namalebula edivayisi yezokwelapha, ilebula nolwazi okufanele luhlinzekwe Ingxenye 1: Izidingo ezijwayelekile
I-International Electrotechnical Commission (IEC), la mazinga alandelayo abhekwa ikakhulukazi.

Isithenjwa Esijwayelekile

Isithenjwa Esijwayelekile

Izihloko

EN 60601-2-54:2009 Imishini kagesi yezokwelapha - Ingxenye 2-54: Izidingo ezikhethekile zokuphepha okuyisisekelo nokusebenza okubalulekile kwemishini ye-X-ray ye-radiography ne-radioscopy
I-IEC60526 Ipulaki yekhebula ene-voltage ephezulu kanye noxhumo lwesokhethi lwemishini ye-X-ray yezokwelapha
I-IEC 60522:1999 Ukunqunywa kokuhlunga okungapheli kwama-X-ray tube assemblies
I-IEC 60613-2010 Izici zikagesi, ezishisayo nezokulayisha zamashubhu e-X-ray e-anode azungezayo ukuze kuhlolwe udokotela
I-IEC60601-1:2006 Izinto zikagesi zezokwelapha - Ingxenye 1: Izidingo ezijwayelekile zokuphepha okuyisisekelo nokusebenza okubalulekile
I-IEC 60601-1-3:2008 Imishini kagesi yezokwelapha - Ingxenye 1-3: Izidingo ezijwayelekile zokuphepha okuyisisekelo nokusebenza okubalulekile - Izinga elihlanganisiwe: Ukuvikelwa kwemisebe kumshini wokuxilonga we-X-ray
I-IEC60601-2-28:2010 Imishini kagesi yezokwelapha - Ingxenye 2-28: Izidingo ezikhethekile zokuphepha okuyisisekelo nokusebenza okubalulekile kwamashubhu e-X-ray ukuze kuhlolwe udokotela
I-IEC 60336-2005 Imishini kagesi yezokwelapha-i-X-ray tube assemblies yokuxilongwa kwezokwelapha-Izici zezindawo okugxilwe kuzo

Incazelo

●Igama libhalwe kanje:

MWHX7010

Ithubhu

A

Isokhethi ye-voltage ephezulu ene-90 degree direction

MWTX70-1.0/2.0-125

B

Isokhethi ye-voltage ephezulu ene-270 degree direction

Idatha Yezobuchwepheshe

Impahla

Ukucaciswa

Okujwayelekile

Amandla okufakwayo okuzenzela we-anode

F 1

F 2

I-IEC 60613

21kW(50/60Hz)

42.5kW(50/60Hz)

 

Umthamo wokugcina ukushisa kwe-anode

100 kJ ( 140kHU)

I-IEC 60613

Umthamo omkhulu wokupholisa we-anode

475W

 
Umthamo wokugcina ukushisa

900kJ

 
Ubukhulu.ukukhishwa kokushisa okuqhubekayo ngaphandle kwe-Air-circular

180W

 
Impahla ye-anodeI-anode top coating material

I-Rhenium-Tungsten-TZM(RTM)

I-Rhenium-Tungsten-(RT)

 
I-engeli eqondiwe (Ref: i-reference axis)

16 °

I-IEC 60788

X-ray tube ukuhlangana filtration inherent

1.5 mm Al / 75kV

I-IEC 60601-1-3

Indawo okugxilwe kuyo amanani okuzisholo

F1(ukugxila okuncane)

F2(ukugxila okukhulu)

I-IEC 60336

1.0

2.0

 
I-X-ray tube nominal voltageI-Radiographic

I-Fluoroscopic

125kV

100kV

I-IEC 60613

Idatha ekushiseni kwe-cathode 

Ubukhulu.okwamanje

I-voltage enkulu

≈ /AC, <20 kHz

 

F1

F 2

 

5.1A

≈5.87.8V

5.1 A

≈7.710.4 V

 
Ukuvuza kwemisebe ku-150 kV / 3mA ebangeni elingu-1m

1.0mGy/h

I-IEC60601-1-3

Inkundla yemisebe ephezulu

573×573mm ku-SID 1m

 
Isisindo somhlangano we-X-ray tube

Cishe.18 kg

 

 

Imibandela yokusebenza, isitoreji kanye nezokuthutha

Imikhawulo

Imikhawulo yokusebenza

Imikhawulo yezokuthutha kanye nesitoreji

Izinga lokushisa le-ambient

Kusuka ku-10kuye 40

Kusuka ku-20to 70

Umswakama ohlobene

≤75%

≤93%

Ukucindezela kwe-Barometric

Ukusuka ku-70kPa kuye ku-106kPa

Ukusuka ku-70kPa kuye ku-106kPa

 

Amanani okhiye we-Stator

1-isigaba stator

Iphuzu lokuhlola

C-M

C-A

Ukuphikiswa okumazombezombe

≈18.0…22.0Ω

≈45.0…55.0Ω

I-Max.permissible operating voltage(ukuqalisa)

230V±10%

Ncoma i-voltage yokusebenza (ukuqalisa)

160V±10%

I-voltage ye-Braking

70VDC

I-voltage esebenzayo ekuchayekeni

80vm

I-voltage esebenzayo ku-fluoroscopy

20V-40Vrms

Isikhathi sokuqalisa (kuye ngesistimu yokuqalisa)

1.2s

Isexwayiso

Isexwayiso sokusebenzisana ne-X-ray Generator

1.Ukuqhekeka Kwezindlu
Ungalokothi ufake amandla alinganiselwe ekuhlanganiseni kweshubhu le-X-ray
Uma amandla okufaka edlula izicaciso zeshubhu, angabangela i-anode ukuthi ishise ngokweqile, ingilazi yeshubhu iphahlazeke, futhi ekugcineni ingase ibangele izinkinga ezinkulu ngenxa yokugcwala ngokweqile okubangelwa ukuhwamuka kukawoyela ngaphakathi komhlangano wezindlu.Esimweni esibucayi lapho ukuqhuma kwezindlu ngenxa yokulayisha ngokweqile, ukushintshwa kokushisa okuphephile kungase kungakwazi ukuvikela ithubhu ye-X-ray, noma ngabe isebenza.
Izingxenye zokuvalwa kwezindlu ziyaphuka.
Ukulimala komuntu okuhlanganisa nokusha ngenxa yokuphuma kwamafutha ashisayo.
Ingozi yomlilo ngenxa yethagethi ye-anode evuthayo.
Ijeneretha yeX-ray kufanele ibe nomsebenzi wokuvikela olawula amandla okufaka ukuze abe ngaphakathi kokucaciswa kweshubhu.

2.Electric Shock
Ukuze ugweme ingozi yokushaqeka kukagesi, lesi sisetshenziswa kufanele sixhunywe kuphela endaweni enomhlaba ovikelayo.

 3.Akukho ukuguqulwa kwalesi sisetshenziswa esivunyelwe!!

Izixwayiso

Qaphela ukusebenzisana ne-X-ray Generator

1.Over Isilinganiselwa
Amandla amaningi kakhulu ekudutshulweni okukodwa angabangela ukuhluleka kokuhlanganiswa kweshubhu ye-X-ray.Kubalulekile ukubuyekeza ngokucophelela ishidi ledatha yezobuchwepheshe futhi ulandele imiyalelo ecacisiwe ukuze ugweme umonakalo.

2.Ukuhlunga Okuphakade
Imithethonqubo yezomthetho icacisa inani eliphelele lokuhlunga elidingekayo kanye nebanga elincane phakathi kwephoyinti lokugxilwa kwe-X-ray nomzimba womuntu.
They kufanele kuthotshelwe umthethonqubo.

3.I-Safety Thermal Switch
Ukuhlanganiswa kweshubhu ye-X-ray kunokushintsha okushisayo kokuphepha ukuze kuvinjwe amandla okufaka engeziwe lapho izindlu zeshubhu zifinyelela ezingeni lokushisa(80yokushintsha-vula.
Iswishi ayinconywa ukuxhuma ikhoyili ye-stator kusekethe yochungechunge.
Noma ngabe iswishi isebenza, ungalokothi ucime amandla esistimu.Iyunithi yokupholisa kufanele isebenze uma isetshenziswa nesistimu.

4.Ukungasebenzi Okungalindelekile
Ukuhlanganiswa kwamashubhu e-X ray kungase kungasebenzi kahle noma kuhluleke kungazelelwe, kudala ingozi yezinkinga ezinkulu.Kubalulekile ukuthi kube nohlelo lwezimo eziphuthumayo olukhona ukuze kuvinjelwe futhi kuxazululwe noma yiziphi izinkinga ezingase ziphakame ngenxa yale ngozi.

5.Uhlelo Olusha
Uma uhlela ukusebenzisa lo mkhiqizo ohlelweni olusha olungacacisiwe kulo mbhalo, noma uma uhlela ukusebenzisa uhlobo oluhlukile lwe-X-ray generator, sicela usithinte ukuze uqinisekise ukuhambisana nokutholakala.

Isexwayiso Ekusebenzeni

1 .I-X-ray Radiationisivikelo

Lo mkhiqizo ufeza izidingo ze-IEC 60601-1-3.

Lo mhlangano weshubhu le-X-ray ukhipha imisebe ye-X-ray ekusebenzeni.Ngakho yizisebenzi ezifanelekayo neziqeqeshiwe kuphela ezivunyelwe ukusebenzisa umhlangano weshubhu le-X-ray.

Imiphumela efanele ye-physiologic ingase ibangele ukulimala esigulini, ukukhiqizwa kwesistimu kufanele kuvikeleke okufanele ukugwema imisebe ye-ionization.

2.I-Dielectric 0il

I-X-ray tube assembly ine-dielectric 0il equkethwe ukuqina kwamandla kagesi aphezulu.Njengoba inobuthi empilweni yomuntu,uma ivezwe endaweni engavinjelwe,kufanele ilahlwe njengokulandelayo kumthethonqubo wendawo.

3 .Operation Atmosphere

Ukuhlanganiswa kweshubhu le-X-ray akuvunyelwe ukusetshenziswa emkhathini wegesi evuthayo noma ebolayo ·

4.Lungisa I-Tube Yamanje

Kuye ngezimo zokusebenza,izici zefilament zingase zishintshwe.

Lolu shintsho lungase luhambisane nokuchayeka kwesilinganiso esiphezulu ekuhlanganisweni kweshubhu le-X-ray.

Ukuze uvimbele ukuhlanganiswa kweshubhu le-X-ray ukuthi lonakaliswe,lungisa i-tube current njalo.

Ngaphandle kwalokho lapho ithubhu ye-X-ray ine-arcing Inkinga ku-alukusetshenziswa isikhathi eside,ukulungiswa kwe-tube current kuyadingeka.

5.X-ray Tube Housing Temperature

Ungathinti indawo yezindlu ze-X-ray ngemva nje kokuhlinzwa ngenxa yokushisa okuphezulu.

Hlala i-X-ray tube ukuze upholiswe.

6.Imikhawulo yokusebenza

Ngaphambi kokusetshenziswa,sicela uqinisekise isimo sendawo ezungezile singaphakathi kweMigomo yokusebenza.

7.Noma yikuphi Ukungasebenzi

Sicela uthinte ku-SAILRAY ngokushesha,uma kukhona ukungasebenzi kahle kwe-X-ray tube assembly kuyabonwa.

8.Ukulahlwa

Ukuhlanganiswa kweshubhu ye-X-ray kanye neshubhu kuqukethe izinto ezifana nowoyela nezinsimbi ezisindayo okufanele kuqinisekiswe ukulahlwa kwazo okuhambisana nemvelo ngokuhambisana nemithetho kazwelonke esebenzayo. Ukulahlwa njengemfucuza yasekhaya noma yezimboni akuvunyelwe. Umkhiqizi unazo. ulwazi lobuchwepheshe oludingekayo futhi izothatha ishubhu ye-X-ray ibuyiselwe ukuze ilahlwe.

Sicela uxhumane nesevisi yamakhasimende ngale njongo.

Amajika wokukhishwa kwe-cathode

Isiqephu esingu-18
Isiqephu esingu-18

Uma(A) Indawo Encane Egxilwe Ngayo

Uma(A) Indawo Enkulu Yokugxila

Ukulayishwa okukodwa nochungechunge

Izimo:Tube Voltage Isigaba Sesithathu

I-Stator Power Frequency 50Hz/60Hz

Isiqephu esingu-20
Isiqephu 22

Ukushisa nokupholisa ijika le-anode

  I-IEC60613

Isiqephu 23

Ukushisa nokupholisa ijika lokuhlanganisa amashubhu e-X-ray

Izimpawu Zezindlu Ezishisayo

Isiqephu 24

Imidwebo enobukhulu beshubhu ye-X-ray

I-SRMWHX7010A

Isiqephu 25

I-SRMWHX7010B

Isiqephu 26

I-Filter Assembly And Cross Section of Port

Isiqephu 27

Izintambo ze-Rotor Connector

Isiqephu 28

  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umlayezo wakho lapha futhi usithumelele wona