Ishubhu le-X-ray lamazinyo CEI OPX105

Ishubhu le-X-ray lamazinyo CEI OPX105

Ishubhu le-X-ray lamazinyo CEI OPX105

Incazelo emfushane:

Uhlobo: Ishubhu le-x-ray le-anode yesiteshi
Isicelo: Kweyunithi ye-x-ray yamazinyo e-panoramic
Imodeli: KL5-0.5-105
Ilingana ne-CEI OPX105
Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Amathegi Omkhiqizo

Incazelo

I-KL5-0.5-105 I-anode emile ye-X-Ray Tube yenzelwe ngokukhethekile iyunithi ye-x-ray yamazinyo ene-panoramic futhi iyatholakala ku-voltage ye-nominal tube engu-105kV ene-single-phase full-wave rectified noma i-DC circuit
Ishubhu elihlanganisiwe lekhwalithi ephezulu elinomklamo wengilazi linendawo eyodwa egxile kakhulu kanye ne-anode eqinisiwe. Umthamo wokugcina ukushisa we-anode ephezulu uqinisekisa uhla olubanzi lwezicelo zokusetshenziswa kwamazinyo okune-panoramic. I-anode eklanyelwe ngokukhethekile ivumela izinga eliphezulu lokushabalalisa ukushisa okuholela ekukhiqizweni okuphezulu kwesiguli kanye nokuphila komkhiqizo isikhathi eside. Isivuno esiphezulu esiqhubekayo phakathi nokuphila kweshubhu yonke siqinisekiswa yithagethi ye-tungsten ephezulu. Ukulula kokuhlanganiswa kwemikhiqizo yesistimu kwenziwa lula ukwesekwa okukhulu kwezobuchwepheshe.

Izicelo

I-KL5-0.5-105 I-anode emile ye-X-Ray Tube yenzelwe ngokukhethekile iyunithi ye-x-ray yamazinyo ene-panoramic futhi iyatholakala ku-voltage ye-nominal tube engu-105kV ene-single-phase full-wave rectified noma i-DC circuit.

Idatha yobuchwepheshe

I-Voltage yeThubhu Ejwayelekile 105kV
I-Voltage Ephambene Ejwayelekile 115kV
Amandla Okufaka Okujwayelekile (kumasekhondi angu-1.0) 950W
Izinga Lokupholisa le-Anode Eliphezulu 250W
Okuqukethwe Okuphezulu Kokushisa kwe-Anode 35kJ
Izici ze-Filament Umax3.5A,5.5±0.5V
Indawo Eqondile Eqanjiwe 0.5 (IEC60336/2005)
I-engeli Eqondiwe
Izinto Eziqondiwe I-Tungsten
Uhlobo lwe-Cathode Intambo engu-W
Ukuhlunga Okuhlala Njalo Okuncane. 0.5mmAl/50 kV(IEC60522/1999)
Ubukhulu Ubude obuyi-140mm nobubanzi obuyi-42mm
Isisindo Amagremu angu-380

Izithombe Ezinemininingwane

I-KL5-0.5-105

Izexwayiso
Funda izixwayiso ngaphambi kokusebenzisa ithubhu
Ishubhu le-X-ray lizokhipha i-X-ray uma linikwe amandla nge-voltage ephezulu, Ulwazi olukhethekile
kufanele kudingeke futhi kufanele kuqashelwe lapho kusingathwa.
1. Uchwepheshe oqeqeshiwe kuphela onolwazi lwe-X-Ray tube okufanele ahlanganise, alondoloze
bese ususa ipayipi.
2. Kufanele kuthathwe ukunakekelwa okwanele ukuze kugwenywe ukushayisana okunamandla nokudlidliza kwepayipi
ngoba yenziwe ngengilazi ebuthakathaka.
3. Ukuvikelwa kwemisebe yeyunithi yeshubhu kumele kuthathwe ngokwanele.
4. Ibanga elincane kakhulu phakathi kwesikhumba (i-SSD) kanye nokuhlunga okuncane kufanele kufane
umthethonqubo futhi uhlangabezane nezindinganiso.
5. Uhlelo kufanele lube nesekethe yokuvikela ukulayisha ngokweqile efanele, ithubhu lingase libe
lonakele ngenxa yokusebenza okukodwa nje kokulayisha ngokweqile.
6. Uma kutholakala noma yikuphi ukukhubazeka ngesikhathi sokuhlinzwa, cisha ngokushesha
ugesi bese uxhumana nonjiniyela wesevisi.
7. Uma ithubhu linesivikelo somthofu, ukulahla isivikelo somthofu kumele kuhlangatshezwane nohulumeni
imithethonqubo.

Inzuzo Yokuncintisana

Umthamo wokugcina ukushisa we-anode ophakeme kanye nokupholisa
Isivuno esiphezulu esiqhubekayo
Isikhathi sokuphila esihle kakhulu


  • Okwedlule:
  • Olandelayo:

  • Inani Elincane Le-oda: 1pc

    Intengo: Ingxoxo

    Imininingwane Yokupakisha: 100pcs ngebhokisi ngalinye noma ngezifiso ngokuya ngobuningi

    Isikhathi Sokulethwa: 1 ~ 2 amasonto ngokuya ngobuningi

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma i-WESTERN UNION

    Amandla Okunikezela: 1000pcs/ngenyanga

    Bhala umlayezo wakho lapha bese uwuthumela kithi