I-China Dental X-ray Tube CEI OPX105 Umkhiqizi Nomhlinzeki | I-Sailray
I-Dental X-ray Tube CEI OPX105

I-Dental X-ray Tube CEI OPX105

I-Dental X-ray Tube CEI OPX105

Incazelo emfushane:

Uhlobo: Ishubhu ye-anode ye-x-ray yesiteshi
Isicelo: Okweyunithi ye-x-ray yamazinyo panoramic
Imodeli: KL5-0.5-105
Ilingana ne-CEI OPX105
Ishubhu yengilazi yekhwalithi ephezulu ehlanganisiwe


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Incazelo

I-KL5-0.5-105 Stationary anode X-Ray Tube yakhelwe ngokukhethekile iyunithi ye-x-ray yamazinyo futhi itholakala ku-voltage yeshubhu engu-105kV enesigaba esisodwa esilungisiwe ngamaza agcwele noma isekethi ye-DC.
Ishubhu yekhwalithi ephezulu edidiyelwe enomklamo wengilazi inendawo eyodwa ebekwe kahle kakhulu kanye ne-anode eqinisiwe. Umthamo ophezulu wokugcina ukushisa kwe-anode uqinisekisa ububanzi bezinhlelo zokusebenza zokufakwa kwamazinyo e-panoramic. I-anode eklanywe ngokukhethekile inika amandla izinga eliphezulu lokulahla ukushisa eliholela ekusebenzeni okuphezulu kwesiguli kanye nempilo ende yomkhiqizo. Isivuno esiqhubekayo somthamo omkhulu phakathi nayo yonke impilo yeshubhu siqinisekiswa yithagethi ye-tungsten ephakeme kakhulu. Ukulula kokuhlanganiswa emikhiqizweni yesistimu kwenziwa lula ukwesekwa kwezobuchwepheshe.

Izinhlelo zokusebenza

I-KL5-0.5-105 Stationary anode X-Ray Tube iklanyelwe ngokukhethekile iyunithi ye-x-ray yamazinyo futhi itholakala ku-voltage yeshubhu engu-105kV enesigaba esisodwa esilungisiwe samaza agcwele noma isekethi ye-DC.

Idatha yobuchwepheshe

I-Nominal Tube Voltage 105kV
I-Nominal Inverse Voltage 115kV
Amandla Okufaka Amagama (ku-1.0s) 950W
Ubukhulu. I-Anode Cooling Rate 250W
Ubukhulu. Okuqukethwe Kokushisa kwe-Anode 35kj
Izici ze-Filament Ifmax3.5A,5.5±0.5V
I-Nominal Focal Spot 0.5 (IEC60336/2005)
I-Engeli eqondiwe
Okuqondisiwe I-Tungsten
Uhlobo lwe-Cathode I-W filament
Ukuhlunga Okuphakade Okuncane. 0.5mmAl/50 kV(IEC60522/1999)
Ubukhulu 140mm ubude by 42mm ububanzi
Isisindo 380 amagremu

Izithombe ezinemininingwane

I-KL5-0.5-105

Izixwayiso
Funda izixwayiso ngaphambi kokusebenzisa ishubhu
Ishubhu ye-X-ray izokhipha i-X -ray uma inikwe amandla kagesi aphezulu, Ulwazi olukhethekile
kufanele kudingekile futhi izixwayiso zidinga ukuthathwa lapho kuyiphatha.
1. Uchwepheshe oqeqeshiwe kuphela onolwazi lweshubhu ye-X-Ray okufanele ahlangane, alondoloze
bese ukhipha i-tube.
2. Ukunakekelwa okwanele kufanele kuthathwe ukuze kugwenywe umthelela onamandla nokudlidliza ku-tube
ngoba yenziwe ngengilazi entekenteke.
3. Ukuvikelwa kwemisebe yeyunithi yeshubhu kufanele kuthathwe ngokwanele.
4. Ibanga eliphansi lesikhumba se-sorce-skin (SSD) kanye nokuhlunga okuncane kufanele kufane ne
umthethonqubo futhi uhlangabezane nezinga.
5. Uhlelo kufanele lube nesifunda sokuvikela ukugcwala ngokweqile, ishubhu lingase libe
yonakele ngenxa yomsebenzi owodwa kuphela wokugcwala.
6. Uma kukhona okungahambi kahle kutholakala ngesikhathi sokuhlinzwa, cisha ucingo ngokushesha
ukunikezwa kwamandla futhi uxhumane nonjiniyela wesevisi.
7. uma ishubhu inesihlangu somthofu, ukulahla isihlangu somthofu kufanele kuhlangane nohulumeni
imithethonqubo.

Inzuzo Yokuncintisana

Umthamo wokugcina ukushisa kwe-anode nokupholisa
Isivuno somthamo ophezulu njalo
Ukuphila okuhle kakhulu


  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umyalezo wakho lapha futhi usithumelele wona