I-China Mobile X-ray Tube Cei OX110-5 Umkhiqizi Nomhlinzeki |I-Sailray
I-Mobile X-ray Tube Cei OX110-5

I-Mobile X-ray Tube Cei OX110-5

I-Mobile X-ray Tube Cei OX110-5

Incazelo emfushane:

Uhlobo: Ishubhu ye-anode ye-x-ray yesiteshi
Isicelo: Iyunithi yokuxilonga evamile ye-x-ray
Imodeli: KL25-0.6/1.5-110
Ilingana ne-CEI OX110-5
Ishubhu yengilazi yekhwalithi ephezulu ehlanganisiwe


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Incazelo

I-KL25-0.6/1.5-110 ithubhu ye-anode emile ye-x-ray yakhelwe ikakhulukazi okokusebenza kwe-C-arm futhi itholakala ku-voltage yeshubhu yegama enefrikhwensi ephezulu noma ijeneretha ye-DC.
Ishubhu yekhwalithi ephezulu ehlanganisiwe enomklamo wengilazi inezindawo ezimbili zokugxila ezibekwe kahle kakhulu kanye ne-anode eqinisiwe.I-anode eklanywe ngokukhethekile inika amandla izinga eliphezulu lokulahla ukushisa eliholela ekusebenzeni okuphezulu kwesiguli kanye nempilo ende yomkhiqizo.Isivuno esiqhubekayo somthamo omkhulu phakathi nayo yonke impilo yeshubhu siqinisekiswa yithagethi ye-tungsten ephakeme kakhulu.Ukulula kokuhlanganiswa emikhiqizweni yesistimu kwenziwa lula ukwesekwa kwezobuchwepheshe.

Izinhlelo zokusebenza

I-KL25-0.6/1.5-110 iklanyelwe ngokukhethekile okokusebenza kwe-C-arm futhi itholakala ku-voltage yeshubhu lokuzisholo nejeneretha ye-DC.

Leli shubhu linokugxila ku-1.5 kanye no-0.6 foci futhi litholakala ku-voltage yeshubhu ephezulu engu-110 kV.

 

Idatha yobuchwepheshe

I-Nominal Tube Voltage 110kV
I-Nominal Focal Spot sinxanxathela yezitolo:0.6 enkulu:1.5(IEC60336/2005)
Izici ze-Filament sinxanxathela yezitolo:Ifmax=4.5A,Uf=5±0.5 enkulu:Ifmax=4.5A,Uf=6.3±0.8V
Amandla Okufaka Amagama (ku-1.0s) sinxanxathela yezitolo:indawo enkulu 0.6kW:indawo 3.5 kW
Isilinganiso Esiqhubekayo Esiphezulu 225W
I-Anode Heat Storage Amandla 30kj
I-Engeli eqondiwe 12°
Okuqondisiwe I-Tungsten
Ukuhlunga Kwemvelo Ubuncane obungu-0.6mmAl bulingana no-75kV
Isisindo cishe 540g

Izithombe ezinemininingwane

KL25-0.6-1.5-110

Imikhawulo Yemvelo

Imikhawulo yokusebenza (kuwoyela we-dielectric):

Izinga lokushisa likawoyela ................................................. ................................................10 ~ 60 °C

I-Oil Pressure ................................................... ................................................. 70 ~ 106 kPa

Imikhawulo yokuthumela kanye nesitoreji: Izinga lokushisa.............................................. .....-40~ 70 °C

Umswakamo ................................................... .................................................. ........ 10 ~ 90 %

(Akukho ukufingqa)

I-Atmospheric Pressure ................................................. ................................. 50 ~ 106 kPa

Inzuzo Yokuncintisana

Umthamo wokugcina ukushisa kwe-anode nokupholisa
Isivuno somthamo ophezulu njalo
Ukuphila okuhle kakhulu


  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umlayezo wakho lapha futhi usithumelele wona