Incazelo emfushane:

Uhlobo: Ishubhu le-x-ray le-anode elimile
Isicelo: Kweyunithi ye-x-ray yamazinyo yangaphakathi komlomo noma umshini we-x-ray we-10mA
Imodeli: RT12-1.5-85
Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Amathegi Omkhiqizo

Incazelo

Leli payipi, i-RT12-1.5-85 lenzelwe iyunithi ye-x-ray yamazinyo yangaphakathi komlomo futhi litholakala nge-voltage yepayipi evamile enesekethe elizilungisayo.

Umthamo wokugcina ukushisa we-anode ephezulu uqinisekisa uhla olubanzi lwezicelo zokufakwa kwamazinyo ngaphakathi komlomo. I-anode eklanyelwe ngokukhethekile ivumela izinga eliphezulu lokushabalalisa ukushisa okuholela ekukhiqizweni okuphezulu kwesiguli kanye nokuphila komkhiqizo isikhathi eside. Isivuno esiphezulu esiqhubekayo phakathi nokuphila kweshubhu yonke siqinisekiswa yithagethi ye-tungsten ephezulu. Ukulula kokuhlanganiswa kwemikhiqizo yesistimu kwenziwa lula ukwesekwa okukhulu kobuchwepheshe.

Izicelo

Leli payipi, i-RT12-1.5-85 lenzelwe iyunithi ye-x-ray yamazinyo yangaphakathi komlomo futhi litholakala nge-voltage yepayipi evamile enesekethe elizilungisayo.

Idatha yobuchwepheshe

I-Voltage yeThubhu Ejwayelekile 85kV
Indawo Eqondile Eqanjiwe 1.5(IEC60336/2005)
Izici ze-Filament Umax=2.6A, Uf=3.0±0.5V
Amandla Okufaka Okujwayelekile (kumasekhondi angu-1.0) 1.8kW
Isilinganiso Esiqhubekayo Esiphezulu 225W
Amandla Okugcina Ukushisa kwe-Anode 10kJ
I-engeli Eqondiwe 23°
Izinto Eziqondiwe I-Tungsten
Ukuhlunga Okungokwemvelo Okulingana okungenani okungu-0.6mmAl ku-75kV
Isisindo cishe 120g

Izithombe Ezinemininingwane

RT12-1.4-85

Izici

Izexwayiso

Funda izixwayiso ngaphambi kokusebenzisa ithubhu

Ishubhu le-X-ray lizokhipha i-X-ray uma linikwe amandla nge-voltage ephezulu, ulwazi olukhethekile kufanele ludingeke futhi kudingeka kuthathwe izinyathelo zokuqapha lapho ulisebenzisa.

1. Uchwepheshe oqeqeshiwe kuphela onolwazi lwe-X-Ray tube okufanele ahlanganise, alondoloze futhi asuse i-tube.

2. Kufanele kuqashelwe ngokwanele ukugwema ukushayisana okunamandla nokudlidliza kwepayipi ngoba lenziwe ngengilazi ebuthakathaka.

3. Ukuvikelwa kwemisebe yeyunithi yeshubhu kumele kuthathwe ngokwanele.

4. Ibanga elincane kakhulu lesikhumba (i-SSD) kanye nokuhlunga okuncane kufanele kuhambisane nomthethonqubo futhi kuhlangabezane nezindinganiso.

5. Uhlelo kufanele lube nesekethe efanele yokuvikela ukulayisha ngokweqile, ithubhu lingase lonakale ngenxa yokusebenza okukodwa kokulayisha ngokweqile.

6. Uma kutholakala noma yikuphi ukukhubazeka ngesikhathi sokusebenza, cisha ugesi ngokushesha bese uxhumana nonjiniyela wesevisi.

7. Uma ithubhu linesivikelo somthofu, ukulahla isivikelo somthofu kumele kuhlangabezane nemithetho kahulumeni.

Inzuzo Yokuncintisana

Umthamo wokugcina ukushisa we-anode ophakeme kanye nokupholisa
Isivuno esiphezulu esiqhubekayo
Isikhathi sokuphila esihle kakhulu
Isitifiketi: SFDA


  • Okwedlule:
  • Olandelayo:

  • Inani Elincane Le-oda: 1pc

    Intengo: Ingxoxo

    Imininingwane Yokupakisha: 100pcs ngebhokisi ngalinye noma ngezifiso ngokuya ngobuningi

    Isikhathi Sokulethwa: 1 ~ 2 amasonto ngokuya ngobuningi

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma i-WESTERN UNION

    Amandla Okunikezela: 1000pcs/ngenyanga