Leli shubhu, i-RT12-1.5-85 yakhelwe iyunithi ye-x-ray ye-intra-oral yamazinyo futhi itholakala ku-voltage yeshubhu lokuzisholo elinomjikelezo ozilungisele wona.
Umthamo ophezulu wokugcina ukushisa kwe-anode uqinisekisa ububanzi bezinhlelo zokusebenza zokufakwa kwamazinyo ngaphakathi emlonyeni. I-anode eklanywe ngokukhethekile inika amandla izinga eliphezulu lokulahla ukushisa eliholela ekusebenzeni okuphezulu kwesiguli kanye nempilo ende yomkhiqizo. Isivuno esiqhubekayo somthamo omkhulu phakathi nayo yonke impilo yeshubhu siqinisekiswa yithagethi ye-tungsten ephakeme kakhulu. Ukulula kokuhlanganiswa emikhiqizweni yesistimu kwenziwa lula ukwesekwa kwezobuchwepheshe.
Leli shubhu, i-RT12-1.5-85 yakhelwe iyunithi ye-x-ray ye-intra-oral yamazinyo futhi itholakala ku-voltage yeshubhu elilinganiselwe elinesekhethi ezilungiselwe yona.
I-Nominal Tube Voltage | 85kV |
I-Nominal Focal Spot | 1.5(IEC60336/2005) |
Izici ze-Filament | Ifmax=2.6A, Uf=3.0±0.5V |
Amandla Okufaka Amagama (ku-1.0s) | 1.8kW |
Isilinganiso Esiqhubekayo Esiphezulu | 225W |
I-Anode Heat Storage Amandla | 10kj |
I-Engeli eqondiwe | 23° |
Okuqondisiwe | I-Tungsten |
Ukuhlunga Kwemvelo | Ubuncane obungu-0.6mmAl bulingana no-75kV |
Isisindo | cishe.120g |
Izixwayiso
Funda izexwayiso ngaphambi kokusebenzisa ishubhu
Ishubhu ye-X-ray izokhipha i-X -ray uma ifakwe amandla kagesi aphezulu, ulwazi olukhethekile kufanele ludingeke futhi kuqashelwe uma uyiphatha.
1. Uchwepheshe oqeqeshiwe kuphela onolwazi lweshubhu le-X-Ray okufanele ahlanganise, agcine futhi asuse ishubhu.
2. Ukunakekelwa okwanele kufanele kuthathwe ukugwema umthelela onamandla nokudlidliza kushubhu ngoba yenziwe ngengilazi ebuthakathaka.
3. Ukuvikelwa kwemisebe ye-tube unit kufanele kuthathwe ngokwanele.
4. Ibanga eliphansi lesikhumba se-sorce-skin (SSD) kanye nokuhlunga okuncane kufanele kufane nomthetho futhi kufinyelele izinga.
5. Uhlelo kufanele lube nesekhethi efanele yokuvikela ukugcwala ngokweqile, ishubhu ingase yonakaliswe ngenxa yokusebenza okukodwa kuphela kokugcwala ngokweqile.
6. Uma kukhona okungahambi kahle kutholakala ngesikhathi sokusebenza, cisha ugesi ngokushesha bese uthintana nonjiniyela wesevisi.
7. uma ishubhu inesihlangu somthofu, ukulahla isihlangu somthofu kufanele sihlangabezane nemithetho kahulumeni.
Umthamo wokugcina ukushisa kwe-anode nokupholisa
Isivuno somthamo ophezulu njalo
Isikhathi sokuphila esihle kakhulu
Isitifiketi: SFDA
Inani elincane le-oda: 1pc
Inani: Ukuxoxisana
Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani
Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani
Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION
Supply Amandla: 1000pcs/ ngenyanga