I-China Medical X-ray Tube CEI OX105-6 Umkhiqizi Nomhlinzeki |I-Sailray
Medical X-ray Tube CEI OX105-6

Medical X-ray Tube CEI OX105-6

Medical X-ray Tube CEI OX105-6

Incazelo emfushane:

Uhlobo: Ishubhu ye-anode ye-x-ray yesiteshi
Imodeli: KL20-2.8-105
Isicelo: Iyunithi yokuxilonga evamile ye-x-ray
Ilingana ne-CEI OX105-6
Ishubhu yengilazi yekhwalithi ephezulu ehlanganisiwe


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Incazelo

I-KL20-2.8-105 ithubhu ye-X-Ray emile iklanyelwe ikakhulukazi iyunithi yokuxilonga evamile ye-x-ray futhi itholakala ku-voltage yeshubhu elincane elinesekhethi ezilungisa ngokwayo.
Ishubhu ye-KL20-2.8-105 inokugxila okukodwa.
Ishubhu yekhwalithi ephezulu edidiyelwe enomklamo wengilazi inendawo eyodwa ebekwe kahle kakhulu kanye ne-anode eqinisiwe.
Umthamo ophezulu wokugcina ukushisa kwe-anode uqinisekisa uhla olubanzi lwezinhlelo zokusebenza ze-x-ray yokuxilonga evamile.I-anode eklanywe ngokukhethekile inika amandla izinga eliphezulu lokulahla ukushisa eliholela ekusebenzeni okuphezulu kwesiguli kanye nempilo ende yomkhiqizo.Isivuno esiqhubekayo somthamo omkhulu phakathi nayo yonke impilo yeshubhu siqinisekiswa yithagethi ye-tungsten ephakeme kakhulu.Ukulula kokuhlanganiswa emikhiqizweni yesistimu kwenziwa lula ukwesekwa kwezobuchwepheshe.

Izinhlelo zokusebenza

I-KL20-2.8-105 ithubhu ye-X-Ray emile iklanyelwe ikakhulukazi iyunithi yokuxilonga evamile ye-x-ray futhi itholakala ku-voltage yeshubhu elincane elinesekhethi ezilungisa ngokwayo.

Idatha yobuchwepheshe

I-Nominal Tube Voltage 105kV
I-Nominal Inverse Voltage 115kV
I-Nominal Focal Spot 2.8 (IEC60336/1993)
Okuqukethwe Kokushisa Okuphezulu kwe-Anode 30000J
Ubukhulu.I-Anode Cooling Rate 250W
I-Engeli eqondiwe 19°
Izici ze-Filament 3.0 - 5.0A, 6.0 - 10.0V
Ukuhlunga Okuphakade Okuncane.0.8mmAl/50KV(IEC60522/1999)
Okuqondisiwe I-Tungsten
Ubukhulu.isevisi yamanje eqhubekayo 3.0mA@100kVAC
Amandla Wokufaka we-Anode Nominal 6000W

Izithombe ezinemininingwane

I-KL20-2.8-105

Inzuzo Yokuncintisana

Umthamo wokugcina ukushisa kwe-anode nokupholisa
Isivuno somthamo ophezulu njalo
Ukuphila okuhle kakhulu


  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umlayezo wakho lapha futhi usithumelele wona