I-China Medical X-ray Tube XD3A Umkhiqizi kanye Nomhlinzeki | I-Sailray
I-Medical X-ray Tube XD3A

I-Medical X-ray Tube XD3A

I-Medical X-ray Tube XD3A

Incazelo emfushane:

Uhlobo: Ishubhu ye-anode ye-x-ray yesiteshi
Isicelo: Iyunithi yokuxilonga evamile ye-x-ray
Imodeli: RT13A-2.6-100 ilingana ne-XD3A-3.5/100
Ishubhu yengilazi yekhwalithi ephezulu ehlanganisiwe


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Incazelo

Leli shubhu, i-RT13A-2.6-100 yakhelwe iyunithi yokuxilonga evamile ye-x-ray futhi itholakala ku-voltage yeshubhu yegama elinesekhethi ezilungiselwe yona.
I-RT13A-2.6-100 tube inokugxila okukodwa.
Ishubhu yekhwalithi ephezulu edidiyelwe enomklamo wengilazi inendawo eyodwa ebekwe kahle kakhulu kanye ne-anode eqinisiwe.
Umthamo ophezulu wokugcina ukushisa kwe-anode uqinisekisa uhla olubanzi lwezinhlelo zokusebenza ze-x-ray yokuxilonga evamile. I-anode eklanywe ngokukhethekile inika amandla izinga eliphezulu lokulahla ukushisa eliholela ekusebenzeni okuphezulu kwesiguli kanye nempilo ende yomkhiqizo. Isivuno esiqhubekayo somthamo omkhulu phakathi nayo yonke impilo yeshubhu siqinisekiswa yithagethi ye-tungsten ephakeme kakhulu. Ukulula kokuhlanganiswa emikhiqizweni yesistimu kwenziwa lula ukwesekwa kwezobuchwepheshe.

Izinhlelo zokusebenza

I-RT13A-2.6-100 iyishubhu ye-X-ray Yokuxilonga Ephathwayo,yakhelwe iyunithi ye-x-ray yokuxilonga evamile futhi itholakalela i-voltage yeshubhu lokuzisholo elinomjikelezo ozilungisele wona.

Idatha yobuchwepheshe

I-Nominal Tube Voltage 105kV
I-Nominal Inverse Voltage 115kV
I-Nominal Focal Spot 2.6(IEC60336/1993)
Okuqukethwe Kokushisa Okuphezulu kwe-Anode 30000J
I-Engeli eqondiwe 19°
Izici ze-Filament 4.5A, 7.0±0.7V
Ukuhlunga Okuphakade Okuncane. 0.8mmAl/50kv(IEC60522/1999)
Okuqondisiwe I-Tungsten
I-Tube Yamanje 50mA

Izithombe ezinemininingwane

I-RT13A-2.6-100

Amashadi anemininingwane

Inzuzo Yokuncintisana

Umthamo wokugcina ukushisa kwe-anode nokupholisa
Isivuno somthamo ophezulu njalo
Ukuphila okuhle kakhulu

Izixwayiso
Funda izixwayiso ngaphambi kokusebenzisa ishubhu
Ishubhu ye-X-ray izokhipha i-X -ray uma inikwe amandla kagesi aphezulu, Ulwazi olukhethekile
kufanele kudingekile futhi izixwayiso zidinga ukuthathwa lapho kuyiphatha.
1. Uchwepheshe oqeqeshiwe kuphela onolwazi lweshubhu ye-X-Ray okufanele ahlangane, alondoloze
bese ukhipha i-tube.
2. Ukunakekelwa okwanele kufanele kuthathwe ukuze kugwenywe umthelela onamandla nokudlidliza ku-tube
ngoba yenziwe ngengilazi entekenteke.
3. Ukuvikelwa kwemisebe yeyunithi yeshubhu kufanele kuthathwe ngokwanele.
4. Ibanga eliphansi lesikhumba se-sorce-skin (SSD) kanye nokuhlunga okuncane kufanele kufane ne
umthethonqubo futhi uhlangabezane nezinga.
5. Uhlelo kufanele lube nesifunda sokuvikela ukugcwala ngokweqile, ishubhu lingase libe
yonakele ngenxa yomsebenzi owodwa kuphela wokugcwala.
6. Uma kukhona okungahambi kahle kutholakala ngesikhathi sokuhlinzwa, cisha ucingo ngokushesha
ukunikezwa kwamandla futhi uxhumane nonjiniyela wesevisi.
7. uma ishubhu inesihlangu somthofu, ukulahla isihlangu somthofu kufanele kuhlangane nohulumeni
imithethonqubo.

  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umyalezo wakho lapha futhi usithumelele wona