Ishubhu ye-X-ray yezokwelapha XD3A

Ishubhu ye-X-ray yezokwelapha XD3A

Ishubhu ye-X-ray yezokwelapha XD3A

Incazelo emfushane:

Uhlobo: Ishubhu le-x-ray le-anode yesiteshi
Isicelo: Kweyunithi ye-x-ray yokuxilonga ejwayelekile
Imodeli: RT13A-2.6-100 elingana ne-XD3A-3.5/100
Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Amathegi Omkhiqizo

Incazelo

Leli payipi, i-RT13A-2.6-100 lenzelwe iyunithi ye-x-ray yokuxilonga ejwayelekile futhi litholakala ku-voltage yepayipi evamile enesekethe elizilungisayo.
Ishubhu le-RT13A-2.6-100 linokugxila okukodwa.
Ishubhu elihlanganisiwe lekhwalithi ephezulu elinomklamo wengilazi linendawo eyodwa egxile kakhulu kanye ne-anode eqinisiwe.
Umthamo wokugcina ukushisa we-anode ephezulu uqinisekisa ububanzi bezicelo zokusetshenziswa kwe-x-ray yokuxilonga okujwayelekile. I-anode eklanyelwe ngokukhethekile ivumela izinga eliphezulu lokushabalalisa ukushisa okuholela ekuphumeni okuphezulu kwesiguli kanye nokuphila komkhiqizo isikhathi eside. Isivuno esiphezulu esiqhubekayo phakathi nokuphila kweshubhu yonke siqinisekiswa yithagethi ye-tungsten enobuningi obukhulu. Ukulula kokuhlanganiswa kwemikhiqizo yesistimu kwenziwa lula ukwesekwa okukhulu kobuchwepheshe.

Izicelo

I-RT13A-2.6-100 iyi-Table Diagnostic stationary anode X-ray tube,yakhelwe iyunithi ye-x-ray yokuxilonga evamile futhi iyatholakala nge-voltage yeshubhu evamile enesekethe ezilungisa yona.

Idatha yobuchwepheshe

I-Voltage yeThubhu Ejwayelekile 105kV
I-Voltage Ephambene Ejwayelekile 115kV
Indawo Eqondile Eqanjiwe 2.6(IEC60336/1993)
Okuqukethwe Okuphezulu Kokushisa kwe-Anode 30000J
I-engeli Eqondiwe 19°
Izici ze-Filament 4.5A, 7.0±0.7V
Ukuhlunga Okuhlala Njalo Okuncane. 0.8mmAl/50kv(IEC60522/1999)
Izinto Eziqondiwe I-Tungsten
I-Tube yamanje 50mA

Izithombe Ezinemininingwane

RT13A-2.6-100

Amashadi anemininingwane

Inzuzo Yokuncintisana

Umthamo wokugcina ukushisa we-anode ophakeme kanye nokupholisa
Isivuno esiphezulu esiqhubekayo
Isikhathi sokuphila esihle kakhulu

Izexwayiso
Funda izixwayiso ngaphambi kokusebenzisa ithubhu
Ishubhu le-X-ray lizokhipha i-X-ray uma linikwe amandla nge-voltage ephezulu, Ulwazi olukhethekile
kufanele kudingeke futhi kufanele kuqashelwe lapho kusingathwa.
1. Uchwepheshe oqeqeshiwe kuphela onolwazi lwe-X-Ray tube okufanele ahlanganise, alondoloze
bese ususa ipayipi.
2. Kufanele kuthathwe ukunakekelwa okwanele ukuze kugwenywe ukushayisana okunamandla nokudlidliza kwepayipi
ngoba yenziwe ngengilazi ebuthakathaka.
3. Ukuvikelwa kwemisebe yeyunithi yeshubhu kumele kuthathwe ngokwanele.
4. Ibanga elincane kakhulu phakathi kwesikhumba (i-SSD) kanye nokuhlunga okuncane kufanele kufane
umthethonqubo futhi uhlangabezane nezindinganiso.
5. Uhlelo kufanele lube nesekethe yokuvikela ukulayisha ngokweqile efanele, ithubhu lingase libe
lonakele ngenxa yokusebenza okukodwa nje kokulayisha ngokweqile.
6. Uma kutholakala noma yikuphi ukukhubazeka ngesikhathi sokuhlinzwa, cisha ngokushesha
ugesi bese uxhumana nonjiniyela wesevisi.
7. Uma ithubhu linesivikelo somthofu, ukulahla isivikelo somthofu kumele kuhlangatshezwane nohulumeni
imithethonqubo.

  • Okwedlule:
  • Olandelayo:

  • Inani Elincane Le-oda: 1pc

    Intengo: Ingxoxo

    Imininingwane Yokupakisha: 100pcs ngebhokisi ngalinye noma ngezifiso ngokuya ngobuningi

    Isikhathi Sokulethwa: 1 ~ 2 amasonto ngokuya ngobuningi

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma i-WESTERN UNION

    Amandla Okunikezela: 1000pcs/ngenyanga

    Bhala umlayezo wakho lapha bese uwuthumela kithi