Incazelo emfushane:

Uhlobo: Ishubhu ye-anode ye-x-ray yesiteshi
Isicelo: Okweyunithi ye-x-ray ejwayelekile yokuxilonga futhi ayatholakala ku-voltage yeshubhu ene-self-rectified circuit.
Imodeli: KL10-0.6/1.8-110
Ilingana ne-CEI 110-15
Ishubhu yengilazi yekhwalithi ephezulu ehlanganisiwe


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Incazelo

I-KL10-0.6/1.8-110 Ishubhu ye-X-Ray ye-anode emile iklanyelwe ngokukhethekile Amayunithi Eselula e-radiography, Amayunithi Aphathekayo we-Radiographic, futhi atholakala ku-voltage yeshubhu enefrikhwensi ephezulu noma ijeneretha ye-DC.
Ishubhu yekhwalithi ephezulu edidiyelwe enomklamo wengilazi inendawo eyodwa ebekwe kahle kakhulu kanye ne-anode eqinisiwe.
Umthamo ophezulu wokugcina ukushisa kwe-anode uqinisekisa ububanzi bezinhlelo zokusebenza zeselula, izinhlelo zokusebenza eziphathekayo. I-anode eklanywe ngokukhethekile inika amandla izinga eliphezulu lokulahla ukushisa eliholela ekusebenzeni okuphezulu kwesiguli kanye nempilo ende yomkhiqizo. Isivuno esiqhubekayo somthamo omkhulu phakathi nayo yonke impilo yeshubhu siqinisekiswa yithagethi ye-tungsten ephakeme kakhulu. Ukulula kokuhlanganiswa emikhiqizweni yesistimu kwenziwa lula ukwesekwa kwezobuchwepheshe.

Izinhlelo zokusebenza

I-KL10-0.6/1.8-110 Ishubhu ye-X-Ray ye-anode emile iklanyelwe ngokukhethekile Amayunithi Eselula e-radiography, Amayunithi Aphathekayo we-Radiographic, futhi atholakala ku-voltage yeshubhu enefrikhwensi ephezulu noma ijeneretha ye-DC.

Idatha yobuchwepheshe

I-Nominal Tube Voltage 110kV
I-Nominal Focal Spot sinxanxathela yezitolo:0.6 enkulu:1.8(IEC60336/2005)
Izici ze-Filament sinxanxathela yezitolo:Ifmax=4.5A,Uf=5±0.5 enkulu:Ifmax=4.5A,Uf=6.3±0.8V
Amandla Okufaka Amagama (ku-1.0s) sinxanxathela yezitolo:indawo enkulu 0.6kW:indawo 5.2 kW
Isilinganiso Esiqhubekayo Esiphezulu 225W
I-Anode Heat Storage Amandla 30kj
I-Engeli eqondiwe 15°
Okuqondisiwe I-Tungsten
Ukuhlunga Kwemvelo Ubuncane obungu-0.6mmAl bulingana no-75kV
Isisindo cishe ama-600g

Izithombe ezinemininingwane

AKL10-0.6-1.8-110

Ukugcina uhlelo lwesinongo

Ngaphambi kokusetshenziswa, inkathi ishubhu ngokuhambisana neshejuli yesinongo enikezwe ngezansi kuze kube yilapho kutholakala amandla kagesi eshubhu adingekayo. Isibonelo esinikiwe - sidinga ukubuyekezwa ngumkhiqizi futhi sicaciswe kudatha sheet yengxenye: Ishejuli yesinongo sokuqala engenayo kanye nesinongo sesikhathi sokungenzi lutho (ngaphezu kwezinyanga ezingu-6) Isifunda: DC (Isekelwe phakathi)

I-KL10 老练图

Lapho ithubhu lamanje lingagxilile kusinongo, vala ngokushesha i-voltage yeshubhu futhi ngemva kwesikhawu semizuzu emi-5 noma ngaphezulu, wandise i-voltage yeshubhu kancane kancane ukusuka ku-voltage ephansi ngenkathi uqinisekisa ukuthi ishubhu lamanje lizinzile. Ukusebenza kwe-voltage okumelana neyunithi yeshubhu kuzokwehliswa njengoba isikhathi sokuchayeka kanye nenani lokusebenza likhula. Ukulandela umthelela okufana nebala kungase kuvele endaweni eqondiswe kwishubhu le-x-ray ngokuphuma kancane phakathi nesinongo. Lezi zimo ziyinqubo eyodwa yokubuyisela ukusebenza kwe-voltage emile ngaleso sikhathi. Ngakho-ke, uma isebenza ngokuzinzile ku-voltage ephezulu yeshubhu yesinongo esilandela kubo, iyunithi yeshubhu ingasetshenziswa ngaphandle kokuphazamiseka ekusebenzeni kwayo kagesi esetshenziswayo.

Inzuzo Yokuncintisana

Umthamo wokugcina ukushisa kwe-anode nokupholisa
Isivuno somthamo ophezulu njalo
Ukuphila okuhle kakhulu


  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga