I-Mobile X-ray Tube CEI 110-15

I-Mobile X-ray Tube CEI 110-15

I-Mobile X-ray Tube CEI 110-15

Incazelo emfushane:

Uhlobo: Ishubhu le-x-ray le-anode yesiteshi
Isicelo: Kweyunithi ye-x-ray yokuxilonga ejwayelekile futhi iyatholakala nge-voltage yeshubhu ejwayelekile enesekethe esizilungisayo.
Imodeli: KL10-0.6/1.8-110
Okulingana ne-CEI 110-15
Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Amathegi Omkhiqizo

Incazelo

Ishubhu le-X-Ray le-KL10-0.6/1.8-110 le-anode engashintshi lenzelwe ngokukhethekile ama-Mobile Units e-radiography, ama-Portable Radiographic Units, futhi litholakala kuma-nominal tube voltage ane-frequency ephezulu noma i-DC generator.
Ishubhu elihlanganisiwe lekhwalithi ephezulu elinomklamo wengilazi linendawo eyodwa egxile kakhulu kanye ne-anode eqinisiwe.
Umthamo wokugcina ukushisa we-anode ephezulu uqinisekisa ububanzi bezinhlelo zokusebenza zeselula, eziphathwayo. I-anode eklanyelwe ngokukhethekile ivumela izinga eliphezulu lokushabalalisa ukushisa okuholela ekukhiqizweni okuphezulu kwesiguli kanye nokuphila komkhiqizo isikhathi eside. Isivuno esiphezulu esiqhubekayo phakathi nokuphila kweshubhu yonke siqinisekiswa yithagethi ye-tungsten ephezulu. Ukulula kokuhlanganiswa kwemikhiqizo yesistimu kwenziwa lula ukwesekwa okukhulu kobuchwepheshe.

Izicelo

Ishubhu le-X-Ray le-KL10-0.6/1.8-110 le-anode engashintshi lenzelwe ngokukhethekile ama-Mobile Units e-radiography, ama-Portable Radiographic Units, futhi litholakala kuma-nominal tube voltage ane-frequency ephezulu noma i-DC generator.

Idatha yobuchwepheshe

I-Voltage yeThubhu Ejwayelekile 110kV
Indawo Eqondile Eqanjiwe sisitolo esikhulu:0.6 enkulu:1.8(IEC60336/2005)
Izici ze-Filament sisitolo esikhulu:Uma ubukhulu = 4.5A, Uf = 5± 0.5 enkulu:Umax=4.5A,Uf=6.3±0.8V
Amandla Okufaka Okujwayelekile (kumasekhondi angu-1.0) sisitolo esikhulu:indawo engu-0.6kW enkulu:indawo engu-5.2kW
Isilinganiso Esiqhubekayo Esiphezulu 225W
Amandla Okugcina Ukushisa kwe-Anode 30kJ
I-engeli Eqondiwe 15°
Izinto Eziqondiwe I-Tungsten
Ukuhlunga Okungokwemvelo Okulingana okungenani okungu-0.6mmAl ku-75kV
Isisindo cishe amagremu angu-600

Izithombe Ezinemininingwane

AKL10-0.6-1.8-110

Ukugcina isimiso sezinongo

Ngaphambi kokusebenzisa, faka i-tube enongiwe ngokuhambisana nesheduli yezinongo enikezwe ngezansi kuze kube yilapho i-voltage ye-tube edingekayo ifinyelelwe. Isibonelo esinikeziwe - sidinga ukubuyekezwa ngumkhiqizi futhi sichazwe eshidini ledatha lengxenye: Isheduli yokuqala yezinongo engenayo kanye nezinongo zesikhathi sokungasebenzi (izinyanga ezingaphezu kwezingu-6) Isekethe: DC (Ibekwe phansi phakathi)

I-KL10 老练图

Uma ugesi we-tube ungazinzile ekusesheni, cisha ngokushesha ugesi we-tube bese kuthi ngemva kwemizuzu emi-5 noma ngaphezulu, wandise ugesi we-tube kancane kancane kusuka kugesi ophansi ngenkathi uqinisekisa ukuthi ugesi we-tube uzinzile. Ukusebenza kogesi wokumelana kweyunithi ye-tube kuzoncishiswa njengoba isikhathi sokuvezwa kanye nenani lokusebenza kukhuphuka. Izimpawu zomthelela ofana nebala zingase zivele ebusweni be-x-ray tube target ngokukhipha okuncane phakathi nosesheni. Lezi zenzakalo ziyinqubo eyodwa yokubuyisela ukusebenza kogesi wokumelana ngaleso sikhathi. Ngakho-ke, uma isebenza kahle kugesi we-tube ophezulu wezisesheni olandela zona, iyunithi ye-tube ingasetshenziswa ngaphandle kokuphazamiseka ekusebenzeni kwayo kagesi okusetshenziswayo.

Inzuzo Yokuncintisana

Umthamo wokugcina ukushisa we-anode ophakeme kanye nokupholisa
Isivuno esiphezulu esiqhubekayo
Isikhathi sokuphila esihle kakhulu


  • Okwedlule:
  • Olandelayo:

  • Inani Elincane Le-oda: 1pc

    Intengo: Ingxoxo

    Imininingwane Yokupakisha: 100pcs ngebhokisi ngalinye noma ngezifiso ngokuya ngobuningi

    Isikhathi Sokulethwa: 1 ~ 2 amasonto ngokuya ngobuningi

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma i-WESTERN UNION

    Amandla Okunikezela: 1000pcs/ngenyanga

    Bhala umlayezo wakho lapha bese uwuthumela kithi