I-China Ejikelezayo Amashubhu we-X-ray anode 21 SRMWTX64-0.6_1.3-130 Umkhiqizi Nomhlinzeki | I-Sailray
I-Anode X-ray Tubes Ezungezayo 21 SRMWTX64-0.6_1.3-130

I-Anode X-ray Tubes Ezungezayo 21 SRMWTX64-0.6_1.3-130

I-Anode X-ray Tubes Ezungezayo 21 SRMWTX64-0.6_1.3-130

Incazelo emfushane:

Uhlobo: Ishubhu ye-anode x-ray ejikelezayo
Isicelo: Ukuze ukuxilongwa Medical x-ray iyunithi
Imodeli: SRMWTX64-0.6/1.3-130
Ilingana ne-IAE X22-0.6/1.3
Ishubhu yengilazi yekhwalithi ephezulu ehlanganisiwe


Imininingwane Yomkhiqizo

Imigomo Yokukhokha Nokuthumela:

Omaka bomkhiqizo

Incazelo

I-SRMWTX64-0.6/1.3-130 ithubhu inokugxila okukabili okudizayinelwe ukusetshenziswa nokuzungezisa kwe-anode yesivinini esijwayelekile sokusebenza kwe-radiographic yamandla aphezulu kanye ne-cine-fluoroscopic.

Ishubhu yekhwalithi ephezulu ehlanganisiwe enomklamo wengilazi inezindawo ezimbili zokugxila ezibekwe kahle kakhulu kanye ne-anode ephoqelelwe engu-64 mm. Umthamo ophezulu wokugcina ukushisa kwe-anode uqinisekisa ububanzi bezicelo zezinqubo zokuxilonga ezijwayelekile ngezinhlelo ezivamile ze-radiographic kanye ne-fluoroscopy.

I-anode eklanywe ngokukhethekile inika amandla izinga eliphezulu lokulahla ukushisa eliholela ekusebenzeni okuphezulu kwesiguli kanye nempilo ende yomkhiqizo.

Isivuno esiqhubekayo somthamo omkhulu phakathi nayo yonke impilo yeshubhu siqinisekiswa yithagethi ehlanganisiwe ye-rhenium-tungsten ephezulu. Ukulula kokuhlanganiswa emikhiqizweni yesistimu kwenziwa lula ukwesekwa kwezobuchwepheshe.

Izinhlelo zokusebenza

I-XD65-0.6/1.3-130 i-X-Ray Tube ejikelezayo ye-anode yakhelwe ikakhulukazi iyunithi ye-x-ray yokuxilongwa Kwezokwelapha.

Imininingwane

I-Voltage Operating Maximum 130KV
Usayizi we-Focal Spot 0.6/1.3
Ububanzi 64 mm
I-Target Material I-RTM
I-Angle ye-Anode 15°
Isivinini Sokuzungezisa 2800RPM
Isitoreji Sokushisa 107kHU
Ukusabalalisa Okuqhubekayo Okuphezulu 300W

Izici ze-Filament

I-filament encane fmax=5.4A ,Uf=7.5±1V
I-filament enkulu Ifmax=5.4A,Uf=10.0±1V
Ukuhlunga Kwemvelo 1mmAL
Amandla Aphezulu 11KW/32KW

Umdwebo Wohlaka

imininingwane

Inzuzo Yokuncintisana

Isivinini esijwayelekile sokuzungezisa i-anode namabherengi athulisiwe
I-anode ye-High density compound (RTM)
Umthamo wokugcina ukushisa kwe-anode nokupholisa
Isivuno somthamo ophezulu njalo
Ukuphila okuhle kakhulu


  • Okwedlule:
  • Olandelayo:

  • Inani elincane le-oda: 1pc

    Inani: Ukuxoxisana

    Imininingwane yokupakisha: 100pcs ibhokisi ngalinye noma egcizelele ngokuvumelana nenani

    Isikhathi Sokulethwa: 1 ~ 2 amaviki ngokuya ngenani

    Imigomo Yokukhokha: 100% T/T kusengaphambili noma WESTERN UNION

    Supply Amandla: 1000pcs/ ngenyanga

    Bhala umyalezo wakho lapha futhi usithumelele wona