Imikhiqizo

Imikhiqizo

  • 100KV High Voltage Cable for X-ray Unit

    100KV High Voltage Cable for X-ray Unit

    I-voltage elinganiselwe: I-100KVDC yezokwelapha Ikhebula le-voltage ephezulu eguquguqukayo

    Izicelo ezijwayelekile zimi kanje:

    1,Imishini ye-x-ray yezokwelapha njenge-x-ray evamile, i-computer tomography kanye ne-angiography

    imishini.

    2,I-x-ray yezimboni neyesayensi noma imishini ye-electron beam efana ne-electron microscopy

    kanye nemishini ye-x-ray diffraction.

    3,Ukuhlola amandla kagesi aphezulu kanye nemishini yokukala.

  • I-X-ray Tube Assembly ilingana ne-E7252X RAD14

    I-X-ray Tube Assembly ilingana ne-E7252X RAD14

    ◆ X-ray tube ukuhlanganiswa kwazo zonke izivivinyo zokuxilonga ngemishini evamile noma yedijithali yeradiographic kanye ne-fluoroscopic
    ◆Ishubhu ye-anode x-ray ejikelezayo enesivinini esikhulu
    ◆Izici zokufaka: 12° Rhenium-Tungsten molybdenum target (RTM)
    ◆Izindawo okugxilwe kuzo: Ezincane 0.6, Ezinkulu: 1.2
    ◆ I-voltage yeshubhu ephezulu: 150kV
    ◆Ihlala nohlobo lwe-IEC60526 yezingxenye zekhebula lamandla kagesi aphezulu
    ◆Ijeneretha kagesi ephezulu kufanele ihambisane ne-IEC60601-2-7
    ◆ Ukuhlelwa kwe-IEC (IEC 60601-1:2005): I-Class I ME IMISEBENZI
  • I-X-RAY TUBE ILINGANA NO-TOSHIBA E7242

    I-X-RAY TUBE ILINGANA NO-TOSHIBA E7242

    Isicelo: X-ray tube umhlangano kuzo zonke izivivinyo zokuxilonga evamile nge ezivamile
    noma iziteshi zokusebenzela ze-radiographic ne-fluoroscopic
    ◆Izici zokufaka : 12.5° Rhenium-Tungsten molybdenum target (RTM)
    ◆Izindawo okugxilwe kuzo: Ezincane 0.6, Ezinkulu: 1.2
    ◆ I-voltage yeshubhu ephezulu : 125kV
    ◆Ihlala nohlobo lwe-IEC60526 yezingxenye zekhebula lamandla kagesi aphezulu
    ◆Ijeneretha kagesi ephezulu kufanele ihambisane ne-IEC60601-2-7
    ◆ Ukuhlelwa kwe-IEC (IEC 60601-1:2005):IZIHLOKO ZESIGABA I ME
  • I-X-ray Exposure Hand Switch Omron C2U HS-01

    I-X-ray Exposure Hand Switch Omron C2U HS-01

    Igama Lomkhiqizo: I-X-ray exposure hand switch
    Igama Lebrand: SAILRAY
    Isitifiketi: CE, ROHS
    Ubukhulu. Okwamanje: 2A
    Ubukhulu. Amandla kagesi: 30VDC
    Uhlobo: Uhlobo lwe-microswitch ye-Omron yangaphakathi
    Ukuphila kukagesi: izikhathi ezingu-200,000
    Ukuphila Komshini: izikhathi ezingu-1,000,000
    Izinto zeShell: Ipulasitiki ye-ABC
    Ubude: 3m, 5m
    Ama-cores: 3 core, 4 core
    Ukwenza ngokwezifiso:Kuyatholakala
    Isixhumi: singalungiswa kusixhumi se-DB9 noma i-RJ45, isixhumi se-RJ11
  • Inkinobho yokusunduza ye-X-ray Shintsha Uhlobo lwe-Omron Microswitch HS-02

    Inkinobho yokusunduza ye-X-ray Shintsha Uhlobo lwe-Omron Microswitch HS-02

    Imodeli: HS-02
    Uhlobo: Ukunyathela okubili
    Ukwakhiwa nezinto ezibonakalayo: Nge-Omron micro switch, ikhava yentambo yekhoyili ye-PU kanye nezintambo zethusi
    Izintambo nentambo yekhoyili: 3cores noma 4cores, 3m noma 5m noma ubude obenziwe ngokwezifiso
    Ikhebula: 24AWG ikhebula noma 26 AWG
    Impilo yemishini: izikhathi eziyizigidi eziyi-1.0
    Impilo kagesi: izikhathi eziyizinkulungwane eziyi-100
    Isitifiketi: CE, RoHS

  • Inkinobho yokusunduza ye-X-ray Shintsha Uhlobo lwe-Omron Microswitch HS-04

    Inkinobho yokusunduza ye-X-ray Shintsha Uhlobo lwe-Omron Microswitch HS-04

    Imodeli: HS-04
    Uhlobo: Ukunyathela okubili
    Ukwakhiwa nezinto ezibonakalayo: Nge-Omron micro switch, ikhava yentambo yekhoyili ye-PU kanye nezintambo zethusi
    Izintambo kanye nentambo yekhoyili: 3cores noma 4 cores, 2.2m noma 5m
    Impilo yemishini: izikhathi eziyizigidi ezingama-50.0
    Impilo kagesi: izikhathi eziyizinkulungwane ezingama-300
    Isitifiketi: CE, ROHS
    Isixhumi: singagxilwa kusixhumi se-RJ45, ipulaki yomoya, isixhumi se-DB9
  • Inkinobho yokusunduza ye-X-ray Shintsha Uhlobo lwe-Omron Microswitch HS-04-1

    Inkinobho yokusunduza ye-X-ray Shintsha Uhlobo lwe-Omron Microswitch HS-04-1

    Imodeli: HS-04-1
    Uhlobo: Ukunyathela okubili ngenkinobho yesibani se-Collimator
    Ukwakhiwa nezinto ezibonakalayo: Nge-Omron micro switch, ikhava yentambo yekhoyili ye-PU kanye nezintambo zethusi
    Izintambo kanye nentambo yekhoyili: 4cores, 2.2m noma 5m
    Impilo yemishini: izikhathi eziyizigidi ezingama-50.0
    Impilo kagesi: izikhathi eziyizinkulungwane ezingama-300
    Isitifiketi: CE, CQC, ROHS
    Isixhumi: singagxilwa ku-RJ45, RJ11 isixhumi
    Singakwenzela wena ngokwezifiso ubude bekhebula nentambo yekhebula.

     

  • Inkinobho yokusunduza ye-X-ray Shintsha Uhlobo lwe-Omron Microswitch 19 HS-01-1

    Inkinobho yokusunduza ye-X-ray Shintsha Uhlobo lwe-Omron Microswitch 19 HS-01-1

    Imodeli: HS-01-1
    Uhlobo: Ukunyathela okukodwa
    Ukwakhiwa nezinto ezibonakalayo: Nge-Omron micro switch, ikhava yentambo yekhoyili ye-PU nezintambo zethusi.

  • Inkinobho yokusunduza ye-X-ray Shintsha Uhlobo lwe-Omron Microswitch 20 HS-03-1

    Inkinobho yokusunduza ye-X-ray Shintsha Uhlobo lwe-Omron Microswitch 20 HS-03-1

    Imodeli: HS-03-1
    Uhlobo: Ukunyathela okukodwa
    Ukwakhiwa nezinto ezibonakalayo: Nge-Omron micro switch, ikhava yentambo yekhoyili ye-PU kanye nezintambo zethusi

  • I-Medical X-ray collimator Automatic x-ray collimator RF202

    I-Medical X-ray collimator Automatic x-ray collimator RF202

    Izici
    Ifanele i-tube voltage 150kV, i-DR digital kanye nemishini yokuxilonga ye-X-ray evamile
     Inkundla yokuthela ngemisebe ye-X-ray inonxande
    Ukuhambisana namazinga afanele kazwelonke nawemboni
    Ukuthembeka okuphezulu nokusebenza kwezindleko eziphezulu
     Ukusebenzisa ungqimba olulodwa namasethi amabili amaqabunga omthofu kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela ama-X-ray
    Ukulungiswa kwensimu ye-irradiation kugesi, ukunyakaza kweqabunga lomthofu kuqhutshwa yi-motor stepping, futhi inkambu yokukhanyisa ihlale ilungiswa.
     Lawula i-beam limiter ngokusebenzisa ukuxhumana kwebhasi ye-CAN noma ukushintshwa kwezinga, noma lawula ngesandla isikhawuli se-beam esiphambi kwakho, futhi isikrini se-LCD sibonisa isimo nemingcele yomkhawulo we-beam.
    Inkambu yokukhanya ebonakalayo yamukela ama-LED ama-bulb anokukhanya okuphezulu
    Isekhethi yokulibaziseka yangaphakathi ingacisha isibani ngokuzenzakalela ngemva kwamasekhondi angu-30 okukhanya, futhi ingacisha isibani mathupha phakathi nesikhathi sokukhanya ukuze kwelule impilo yesibani futhi yonge amandla.
    Uxhumano lwemishini olulula futhi oluthembekile nge-X-ray tube, kulula ukulungisa

  • I-Medical X-ray Collimator Automatic X-ray Collimator SR305

    I-Medical X-ray Collimator Automatic X-ray Collimator SR305

    Ifanele izinto ezijwayelekile zokuxilonga ze-X-ray ezinamashubhu kagesi angu-150kV
     Inkundla yokuthela ngemisebe ye-X-ray inonxande
    Ukuhambisana namazinga afanele kazwelonke nawemboni
    Usayizi omncane
    Ukuthembeka okuphezulu nokusebenza kwezindleko eziphezulu
     Ukusebenzisa izingqimba ezintathu namasethi amabili amaqabunga omthofu kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela ama-X-ray
    Ukulungiswa kwendawo yokuthela kwenziwa ngesandla, futhi inkambu yokuthela imisebe ihlale ilungiseka.
    Inkambu yokukhanya ebonakalayo isebenzisa ama-LED ama-bulbs akhanya kakhulu
    Isekhethi yokulibaziseka yangaphakathi ingacisha isibani ngokuzenzakalela ngemva kwamasekhondi angu-30 okukhanya, futhi ingacisha isibani mathupha phakathi nesikhathi sokukhanya ukuze kwelule impilo yesibani futhi yonge amandla.
    Uxhumano lwemishini olulula futhi oluthembekile nge-X-ray tube, kulula ukulungisa

  • I-Medical X-ray Collimator Manual X-ray beam limitter SR302

    I-Medical X-ray Collimator Manual X-ray beam limitter SR302

    Ifanele izinto ezijwayelekile zokuxilonga ze-X-ray ezinamashubhu kagesi angu-150kV
     Inkundla yokuthela ngemisebe ye-X-ray inonxande
    Ukuhambisana namazinga afanele kazwelonke nawemboni
    Usayizi omncane
    Ukuthembeka okuphezulu nokusebenza kwezindleko eziphezulu
     Ukusebenzisa izendlalelo ezimbili namasethi amabili amaqabunga omthofu kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela ama-X-ray
    Ukulungiswa kwendawo yokuthela kwenziwa ngesandla, futhi inkambu yokuthela imisebe ihlale ilungiseka.
    Inkambu yokukhanya ebonakalayo isebenzisa ama-LED ama-bulbs akhanya kakhulu
    Isekhethi yokulibaziseka yangaphakathi ingacisha isibani ngokuzenzakalela ngemva kwamasekhondi angu-30 okukhanya, futhi ingacisha isibani mathupha phakathi nesikhathi sokukhanya ukuze kwelule impilo yesibani futhi yonge amandla.
    Uxhumano lwemishini olulula futhi oluthembekile nge-X-ray tube, kulula ukulungisa