I-X-ray Tube Housing Assembly TOSHIBA E7239X
◆Ukuhlanganiswa kweshubhu le-X-ray kuzo zonke izivivinyo zokuxilonga ezijwayelekile ngezindawo zokusebenza ezivamile noma zedijithali ze-x-ray kanye ne-fluoroscopic
◆Izici zokufakwa: 16° Rhenium-Tungsten molybdenum target (RTM)
◆Izindawo ezigxile: Ezincane 1.0, Ezinkulu: 2.0
◆I-voltage enkulu yepayipi:125kV
◆Ihambisana nezimbozo zekhebula ezinamandla aphezulu zohlobo lwe-IEC60526
◆Ijeneretha ye-voltage ephezulu kufanele ivumelane ne-IEC60601-2-7
◆Ukuhlukaniswa kwe-IEC (IEC 60601-1:2005):IMISEBENZI YE-Class I ME
Ingilazi ye-X-ray Shielding Lead 37 ZF3
Inombolo Yemodeli: ZF3
Ukulingana kwe-Lead: 0.22mmpb
Usayizi Omkhulu: 2.4*1.2m
Ubuningi: 4.46gm/Cm
Ubukhulu: 8-150mm
Isitifiketi: CE
Isicelo: Ingilazi Yokuvikela Evikelayo Ye-X Ray Yezokwelapha
Izinto: Ingilazi Yokuhola
Ukucaca: ngaphezu kuka-85%
Izimakethe Zokuthumela Ngaphandle: Emhlabeni Wonke
Inkinobho ye-X-ray Cindezela inkinobho ye-Omron Microswitch Uhlobo lwe-HS-02-1
Imodeli: HS-02-1
Uhlobo: Ukunyathela okukodwa
Ukwakhiwa nezinto zokwakha: Nge-Omron micro switch, isembozo sentambo yekhoyili ye-PU kanye nezintambo zethusi.
Ngithole imvume ye-CE ROHS
Ubude bekhebula bungenziwa ngezifiso ngokuya ngezidingo ezahlukene
Inkinobho ye-X-ray Cindezela Shintsha Uhlobo Lomshini 19 HS-01-1
Imodeli: HS-01-1
Uhlobo: Ukunyathela okukodwa
Ukwakhiwa nezinto zokwakha: Nge-switch yemishini, isembozo sentambo yekhoyili ye-PU kanye nezintambo zethusi
Ingalungiswa ku-rj11, rj12, rj45, isixhumi se-DB9 njalo njalo.
Ubude bekhebula bungenziwa ngokwezifiso ukuze kuhlangatshezwane nezidingo ezithile kanye nezintandokazi.
Ukuvunyelwa kwe-CE ROHS
Ishubhu ye-X-ray yamazinyo ebanzi i-TOSHIBA D-051
Uhlobo: Ishubhu le-x-ray le-anode elimile
Isicelo: Kweyunithi ye-x-ray yamazinyo e-panoramic
Imodeli: KL5A-0.5-105
Ilingana ne-TOSHIBA D-051
Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe
Ishubhu le-X-ray lamazinyo CEI OPX105
Uhlobo: Ishubhu le-x-ray le-anode yesiteshi
Isicelo: Kweyunithi ye-x-ray yamazinyo e-panoramic
Imodeli: KL5-0.5-105
Ilingana ne-CEI OPX105
Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe
I-Mobile X-ray Tube Cei OX110-5
Uhlobo: Ishubhu le-x-ray le-anode yesiteshi
Isicelo: Kweyunithi ye-x-ray yokuxilonga ejwayelekile
Imodeli: KL25-0.6/1.5-110
Ilingana ne-CEI OX110-5
Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe
I-Medical X-ray Tube CEI OX105-6
Uhlobo: Ishubhu le-x-ray le-anode yesiteshi
Imodeli: KL20-2.8-105
Isicelo: Kweyunithi ye-x-ray yokuxilonga ejwayelekile
Ilingana ne-CEI OX105-6
Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe
Ishubhu ye-X-ray yezokwelapha XD3A
Uhlobo: Ishubhu le-x-ray le-anode yesiteshi
Isicelo: Kweyunithi ye-x-ray yokuxilonga ejwayelekile
Imodeli: RT13A-2.6-100 elingana ne-XD3A-3.5/100
Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe
I-Mobile X-ray Tube CEI 110-15
Uhlobo: Ishubhu le-x-ray le-anode yesiteshi
Isicelo: Kweyunithi ye-x-ray yokuxilonga ejwayelekile futhi iyatholakala nge-voltage yeshubhu ejwayelekile enesekethe esizilungisayo.
Imodeli: KL10-0.6/1.8-110
Okulingana ne-CEI 110-15
Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe
Ishubhu ye-X-ray yamazinyo Xd2
Uhlobo: Ishubhu le-x-ray le-anode elimile
Isicelo: Kweyunithi ye-x-ray yamazinyo yangaphakathi komlomo noma umshini we-x-ray we-10mA
Imodeli: RT12-1.5-85
Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe
Ishubhu ye-X-ray yamazinyo eneGridi
Uhlobo: Ishubhu le-x-ray le-anode yesiteshi
Isicelo: Kweyunithi ye-x-ray yamazinyo yangaphakathi komlomo
Imodeli: KL2-0.8-70G
Ilingana ne-CEI OCX/65-G
Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe