  • Izindlu zokuzungeza amashubhu anode

    Izindlu zokuzungeza amashubhu anode

    Igama lomkhiqizo: X-ray tube Housing
    Izingxenye eziyinhloko: Umkhiqizo uqukethe igobolondo leshubhu, ikhoyili ye-stator, isokhethi kagesi ophezulu, isilinda esiholayo, ipuleti lokuvala, indandatho yokuvala, iwindi le-ray, idivayisi yokwandisa nokufinyela, isitsha somthofu, ipuleti lokucindezela, iwindi lomthofu, ikhava yokugcina, ubakaki we-cathode, i-thrust. isikulufu sendandatho, njll.
    Impahla ye-coating yezindlu: I-Thermosetting Powder Coatings
    Umbala wezindlu: Mhlophe
    Ukwakheka kodonga lwangaphakathi:Upende Obomvu Ovikelayo
    Umbala wekhava yokugcina: Ompunga oyisiliva

  • I-X-ray shielding Lead glass 36 ZF2

    I-X-ray shielding Lead glass 36 ZF2

    Inombolo yomthetho: ZF2
    Ukulingana okuholayo: 0.22mmpb
    Ubukhulu Ubukhulu: 2.4*1.2m
    Ukuminyana: 4.12gm/Cm
    Ubukhulu: 8-150mm
    Isitifiketi: CE
    Isicelo: Medical X Ray Radiation Protective lead Glass
    Material: Lead Glass
    Ukungafihli: ngaphezu kwama-85%
    Izimakethe Zokuthekelisa: Umhlaba jikelele

  • Inkinobho yokusunduza ye-X-ray Shintsha Uhlobo Lomshini HS-01

    Inkinobho yokusunduza ye-X-ray Shintsha Uhlobo Lomshini HS-01

    Imodeli: HS-01
    Uhlobo: Ukunyathela okubili
    Ukwakhiwa kanye nempahla: Ngengxenye yemishini, ikhava yentambo yekhoyili ye-PU kanye nezintambo zethusi
    Izintambo nentambo yekhoyili: 3cores noma 4cores, 3m noma 5m noma ubude obenziwe ngokwezifiso
    Ikhebula: 24AWG ikhebula noma 26 AWG
    Impilo yemishini: izikhathi eziyizigidi eziyi-1.0
    Impilo kagesi: izikhathi eziyizinkulungwane ezingama-400
    Isitifiketi: CE, RoHS

  • I-Dental X-ray Tube CEI Ox_70-P

    I-Dental X-ray Tube CEI Ox_70-P

    Uhlobo: Ishubhu ye-anode emile ye-x-ray
    Isicelo: Okweyunithi ye-x-ray yamazinyo yangaphakathi ngomlomo
    Imodeli: KL1-0.8-70
    Ilingana ne-CEI OC70-P
    Ishubhu yengilazi yekhwalithi ephezulu ehlanganisiwe

    Leli shubhu line-focus engu-0.8, futhi litholakala ngamandla e-tube voltage 70 kV.

    Kufakwe endaweni ebiyelwe efanayo ne-high voltage transformer

  • I-Anode X-ray Tubes Ezungezayo 21 SRMWTX64-0.6_1.3-130

    I-Anode X-ray Tubes Ezungezayo 21 SRMWTX64-0.6_1.3-130

    Uhlobo: Ishubhu ye-anode x-ray ejikelezayo
    Isicelo: Ukuze ukuxilongwa Medical x-ray iyunithi
    Imodeli: SRMWTX64-0.6/1.3-130
    Ilingana ne-IAE X22-0.6/1.3
    Ishubhu yengilazi yekhwalithi ephezulu ehlanganisiwe

  • Amashubhu eX-ray e-Anode ajikelezayo 22 MWTX64-0.3_0.6-130

    Amashubhu eX-ray e-Anode ajikelezayo 22 MWTX64-0.3_0.6-130

    Uhlobo: Ishubhu ye-anode x-ray ejikelezayo
    Isicelo: Iyunithi ye-x-ray yokuxilongwa kwezokwelapha, uhlelo lwe-C-arm x-ray
    Imodeli: MWTX64-0.3/0.6-130
    Ilingana ne-IAE X20P
    Ishubhu yengilazi yekhwalithi ephezulu ehlanganisiwe

  • Amashubhu e-Anode X-ray ajikelezayo MWTX73-0.6_1.2-150H

    Amashubhu e-Anode X-ray ajikelezayo MWTX73-0.6_1.2-150H

    Ishubhu ye-X-ray ye-anode ejikelezayo ngenjongo yezinqubo zokuxilonga ezijwayelekile ze-X-ray.

    I-Rhenium-tungsten ecutshungulwe ngokukhethekile ibhekane nethagethi ye-molybdenum engu-73mm ububanzi.

    Leli shubhu line-foci 0.6 no-1.2 futhi litholakala ku-voltage yeshubhu ephezulu engu-150 kV.

    Ilingana ne:ToshibaE7252 Varian RAD-14 Siemens RAY-14 IAE RTM782HS

  • I-Anode X-ray Ejikelezayo Amashubhu MWTX64-0.8_1.8-130

    I-Anode X-ray Ejikelezayo Amashubhu MWTX64-0.8_1.8-130

    Uhlobo: Ishubhu ye-anode x-ray ejikelezayo
    Isicelo: Ukuze ukuxilongwa Medical x-ray iyunithi
    Imodeli: MWTX64-0.8/1.8-130
    Ilingana ne-IAE X20
    Ishubhu yengilazi yekhwalithi ephezulu ehlanganisiwe

  • I-HV Cable Receptacle 60KV HV Receptacle CA11

    I-HV Cable Receptacle 60KV HV Receptacle CA11

    Isokhethi yekhebula elinamandla kagesi angu-75KV womshini we-X ray iyincenye yekhebula lezokwelapha elinamandla kagesi aphezulu, lingangena esikhundleni sesokhethi evamile Ekalwe ugesi ongu-75kvdc.Kodwa ubukhulu bayo buncane kakhulu kunesokhethi evamile elinganiselwe ye-voltage 75KVDC.

  • Ishubhu ye-X-ray Yamazinyo i-Toshiba D-041

    Ishubhu ye-X-ray Yamazinyo i-Toshiba D-041

    Uhlobo: Ishubhu ye-anode emile ye-x-ray
    Isicelo: Okweyunithi ye-radiography yamazinyo
    Imodeli: RT11-0.4-70
    Ilingana ne-TOSHIBA D-041

    Kufakwe endaweni ebiyelwe efanayo ne-high voltage transformer

  • Ishubhu ye-x-ray yamazinyo CEI OX_70-M

    Ishubhu ye-x-ray yamazinyo CEI OX_70-M

    Uhlobo: Ishubhu ye-anode emile ye-x-ray
    Isicelo: Okweyunithi ye-x-ray yamazinyo yangaphakathi ngomlomo
    Imodeli: KL27-0.8-70
    Ilingana ne-CEI OC70-M
    Ingilazi ye-tube-SCHOTT yekhwalithi ephezulu ehlanganisiwe