Imikhiqizo

Imikhiqizo

  • I-collimator ye-X-ray yezokwelapha I-collimator ye-x-ray ezenzakalelayo i-RF202

    I-collimator ye-X-ray yezokwelapha I-collimator ye-x-ray ezenzakalelayo i-RF202

    Izici
    Ifanelekela i-tube voltage engu-150kV, imishini yokuhlola yedijithali ye-DR kanye ne-X-ray evamile
     Insimu yokukhanya kwe-X-ray ingunxande
    Ukuhambisana nezindinganiso ezifanele zikazwelonke nezemboni
    Ukuthembeka okuphezulu kanye nokusebenza okubiza kakhulu
    Ukusebenzisa ungqimba olulodwa kanye namasethi amabili amaqabunga e-lead kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela ama-X-ray
    Ukulungiswa kwensimu yokukhanyisela ngogesi, ukunyakaza kweqabunga eliholayo kuqhutshwa yinjini yokunyathela, kanti insimu yokukhanyisela ngogesi ihlale ilungiseka
     Lawula umkhawulo we-beam ngokusebenzisa ukuxhumana kwebhasi le-CAN noma izinga lokushintsha, noma ulawule ngesandla umkhawulo we-beam ophambi kwakho, bese isikrini se-LCD sibonisa isimo kanye nemingcele yomkhawulo we-beam
    Inkambu yokukhanya ebonakalayo isebenzisa ama-LED bulbs ngokukhanya okuphezulu
    Isekethe yokulibaziseka yangaphakathi ingacima isibani ngokuzenzakalelayo ngemva kwemizuzwana engama-30 yokukhanya, futhi ingacima isibani ngesandla ngesikhathi sokukhanya ukuze kwandiswe impilo yesibani futhi kongiwe amandla.
    Ukuxhumana okulula nokuthembekile kwemishini nge-X-ray tube, kulula ukuyilungisa

  • I-Collimator ye-X-ray yezokwelapha i-Collimator ye-X-ray ezenzakalelayo i-SR305

    I-Collimator ye-X-ray yezokwelapha i-Collimator ye-X-ray ezenzakalelayo i-SR305

    Ifanele imishini yokuxilonga ye-X-ray evamile ene-voltage yeshubhu engu-150kV
     Insimu yokukhanya kwe-X-ray ingunxande
    Ukuhambisana nezindinganiso ezifanele zikazwelonke nezemboni
    Usayizi omncane
    Ukuthembeka okuphezulu kanye nokusebenza okubiza kakhulu
    Ukusebenzisa izendlalelo ezintathu namasethi amabili amaqabunga e-lead kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela imisebe ye-X
    Ukulungiswa kwensimu yokukhanyisela kwenziwa ngesandla, kanti insimu yokukhanyisela ihlale ilungiseka
    Inkambu yokukhanya ebonakalayo isebenzisa amabhalbhu e-LED akhanya kakhulu
    Isekethe yokulibaziseka yangaphakathi ingacima isibani ngokuzenzakalelayo ngemva kwemizuzwana engama-30 yokukhanya, futhi ingacima isibani ngesandla ngesikhathi sokukhanya ukuze kwandiswe impilo yesibani futhi kongiwe amandla.
    Ukuxhumana okulula nokuthembekile kwemishini nge-X-ray tube, kulula ukuyilungisa

  • Umshini wokulawula imisebe ye-X-ray Collimator wezokwelapha i-SR302

    Umshini wokulawula imisebe ye-X-ray Collimator wezokwelapha i-SR302

    Ifanele imishini yokuxilonga ye-X-ray evamile ene-voltage yeshubhu engu-150kV
     Insimu yokukhanya kwe-X-ray ingunxande
    Ukuhambisana nezindinganiso ezifanele zikazwelonke nezemboni
    Usayizi omncane
    Ukuthembeka okuphezulu kanye nokusebenza okubiza kakhulu
    Ukusebenzisa izendlalelo ezimbili kanye namasethi amabili amaqabunga e-lead kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela imisebe ye-X
    Ukulungiswa kwensimu yokukhanyisela kwenziwa ngesandla, kanti insimu yokukhanyisela ihlale ilungiseka
    Inkambu yokukhanya ebonakalayo isebenzisa amabhalbhu e-LED akhanya kakhulu
    Isekethe yokulibaziseka yangaphakathi ingacima isibani ngokuzenzakalelayo ngemva kwemizuzwana engama-30 yokukhanya, futhi ingacima isibani ngesandla ngesikhathi sokukhanya ukuze kwandiswe impilo yesibani futhi kongiwe amandla.
    Ukuxhumana okulula nokuthembekile kwemishini nge-X-ray tube, kulula ukuyilungisa

  • I-Collimator ye-X-ray yezokwelapha i-Collimator ye-X-ray ezenzakalelayo engu-34 SRF202AF

    I-Collimator ye-X-ray yezokwelapha i-Collimator ye-X-ray ezenzakalelayo engu-34 SRF202AF

    Uhlobo: SRF202AF
    Kusebenza ku-C ARM
    Ububanzi obukhulu bokumbozwa kwensimu ye-X-ray: 440mm×440mm
    I-Voltage Ephezulu: 150KV
    I-SID: 60mm

  • I-Collimator ye-X-ray yezokwelapha i-Collimator ye-X-ray ezenzakalelayo i-SR301

    I-Collimator ye-X-ray yezokwelapha i-Collimator ye-X-ray ezenzakalelayo i-SR301

    Izici
    Ifanelekela i-tube voltage engu-150kV, imishini yokuhlola yedijithali ye-DR kanye ne-X-ray evamile
     Insimu yokukhanya kwe-X-ray ingunxande
    Ukuhambisana nezindinganiso ezifanele zikazwelonke nezemboni
    Ukuthembeka okuphezulu kanye nokusebenza okubiza kakhulu
     Kusetshenziswa izendlalelo ezimbili kanye namasethi amabili amaqabunga e-lead kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela imisebe ye-X. Amaqabunga e-lead aphezulu angangena efasiteleni leshubhu le-X-ray, elingavikela imisebe ehlakazekile elahlekile ngempumelelo.
    Ukulungiswa kwensimu yokukhanyisa kwenziwa ngesandla, kulungiseka njalo
    Inkambu yokukhanya ebonakalayo isebenzisa amabhalbhu e-LED akhanya kakhulu
    Isekethe yokulibaziseka yangaphakathi ingacima isibani ngokuzenzakalelayo ngemva kwemizuzwana engama-30 yokukhanya, futhi ingacima isibani ngesandla ngesikhathi sokukhanya ukuze kwandiswe impilo yesibani futhi kongiwe amandla.
    Ukuxhumana okulula nokuthembekile kwemishini nge-X-ray tube, kulula ukuyilungisa

  • Incwadi Yezokwelapha ye-X-ray Collimator X-ray Collimator SR103

    Incwadi Yezokwelapha ye-X-ray Collimator X-ray Collimator SR103

    Izici
    Ifanele imishini yokuxilonga ye-X-ray ephathekayo noma ephathekayo ene-voltage yeshubhu engu-120kV
     Insimu yokukhanya kwe-X-ray ingunxande
    Ukuhambisana nezindinganiso ezifanele zikazwelonke nezemboni
    Usayizi omncane
    Ukuthembeka okuphezulu kanye nokusebenza okubiza kakhulu
    Ukusebenzisa ungqimba olulodwa kanye namasethi amabili amaqabunga e-lead kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela ama-X-ray
    Ukulungiswa kwensimu yokukhanyisela kwenziwa ngesandla, kanti insimu yokukhanyisela ihlale ilungiseka
    Inkambu yokukhanya ebonakalayo isebenzisa amabhalbhu e-LED akhanya kakhulu
    Ukuxhumana okulula nokuthembekile kwemishini nge-X-ray tube, kulula ukuyilungisa

  • Umshini wokulawula imisebe ye-X-ray Collimator wezokwelapha i-SR202

    Umshini wokulawula imisebe ye-X-ray Collimator wezokwelapha i-SR202

    Izici
    Ihambisana nemishini yokuxilonga ye-X-ray esebenzisa i-voltage yeshubhu engu-150kV, okuhlanganisa izinhlelo zedijithali ze-DR kanye nezinhlelo ezivamile
     Insimu yokukhanya kwe-X-ray ingunxande
    Ukuhambisana nezindinganiso ezifanele zikazwelonke nezemboni
    Usayizi omncane
    Ukuthembeka okuphezulu kanye nokusebenza okubiza kakhulu
    Isebenzisa ungqimba olulodwa, amasethi amabili amaqabunga e-lead kanye nomklamo okhethekile wokuvikela kwangaphakathi ukuvimba ama-X-ray.
    Ukulungiswa kwensimu yokukhanyisa kwenziwa ngesandla, kulungiseka njalo
    Inkambu yokukhanya ebonakalayo isebenzisa amabhalbhu e-LED
    Isekethe yokulibaziseka eyakhelwe ngaphakathi icima isibani ngokuzenzakalelayo imizuzwana engama-30 ngemva kokuvulwa, futhi inketho yokucima isibani ngesandla ngesikhathi sokusebenza nayo iyatholakala. Lezi zici zenzelwe ukwandisa isikhathi sokuphila kwesibani nokunciphisa ukusetshenziswa kwamandla.

  • Inkinobho ye-X-ray Cindezela inkinobho ye-Omron Microswitch Uhlobo 14 HS-01

    Inkinobho ye-X-ray Cindezela inkinobho ye-Omron Microswitch Uhlobo 14 HS-01

    Imodeli: HS-01
    Uhlobo: Izitebhisi ezimbili
    Ukwakhiwa nezinto zokwakha: Nge-Omron micro switch, isembozo sentambo ye-PU coil kanye nezintambo zethusi
    Izintambo kanye nentambo yekhoyili: ama-cores angu-3 noma ama-cores angu-4, ubude obungu-3m ​​noma obungu-5m noma obunziwe ngokwezifiso
    Ikhebula: Ikhebula elingu-24AWG noma ikhebula elingu-26 AWG
    Impilo yemishini: izikhathi eziyizigidi eziyi-1.0
    Impilo kagesi: izikhathi eziyizinkulungwane ezingu-400
    Isitifiketi: CE, RoHS

  • Ikhebula le-75KVDC High Voltage WBX-Z75-T

    Ikhebula le-75KVDC High Voltage WBX-Z75-T

    I-High Voltage Cable Assemblies yeMishini ye-X-ray iyi-medical high voltage cable assembly elinganiselwa ku-100 kVDC, uhlobo lokuphila kahle (ukuguga) oluvivinywa ezimweni ezinzima kakhulu.

    Izicelo ezijwayelekile zale ntambo ye-conductor engu-3 ene-plug engu-90º high voltage yilezi ezilandelayo:

    1. Imishini ye-x-ray yezokwelapha efana ne-x-ray ejwayelekile, i-computer tomography kanye nemishini ye-angiography.

    2. Imishini ye-x-ray noma ye-electron beam yezimboni neyesayensi njenge-electron microscopy kanye nemishini ye-x-ray diffraction.

    3. Ukuhlolwa kwamandla aphezulu kanye nemishini yokulinganisa enamandla aphansi.

  • Ikhebula le-Mammography High Voltage WBX-Z60-T02

    Ikhebula le-Mammography High Voltage WBX-Z60-T02

    Imihlangano yekhebula le-voltage ephezulu ihlanganisa izintambo nama-plug ane-voltage ephezulu
    Izintambo ze-high-voltage zakhiwe yizingxenye ezilandelayo eziyinhloko:
    a) Umqhubi;
    b) ungqimba lokuvikela;
    c) ungqimba lokuvikela;
    d) Isigqoko.
    Ipulaki kufanele ibe nezingxenye ezilandelayo eziyinhloko:
    a) Izibambo;
    b) umzimba wepulagi;
    c) iphinikhodi

  • Amashubhu e-X-ray e-Anode ajikelezayo MWTX70-1.0_2.0-125

    Amashubhu e-X-ray e-Anode ajikelezayo MWTX70-1.0_2.0-125

    Uhlobo: Ishubhu le-x-ray le-anode elijikelezayo
    Isicelo: Iyunithi ye-x-ray yokuxilongwa kwezokwelapha
    Imodeli: MWTX70-1.0/2.0-125
    Ilingana ne-Toshiba E-7239
    Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe

    Ukuvunyelwa kwe-CE

  • Ishubhu ye-X-ray ye-Bone Desimeter Brand Bx-1

    Ishubhu ye-X-ray ye-Bone Desimeter Brand Bx-1

    Uhlobo: Ishubhu le-x-ray le-anode yesiteshi
    Isicelo: Yakhelwe ngokukhethekile uhlelo lwe-x-ray olune-densimeter yethambo ukuze kusetshenziswe i-radiography.
    Imodeli: RT2-0.5-80
    Ilingana ne-BRAND X-RAY BX-1
    Ishubhu yengilazi esezingeni eliphezulu ehlanganisiwe