
I-Medical X-ray collimator Automatic x-ray collimator RF202
Izici
Ifanele i-tube voltage 150kV, i-DR digital kanye nemishini yokuxilonga ye-X-ray evamile
Inkundla yokuthela ngemisebe ye-X-ray inonxande
Ukuhambisana namazinga afanele kazwelonke nawemboni
Ukuthembeka okuphezulu nokusebenza kwezindleko eziphezulu
Ukusebenzisa ungqimba olulodwa namasethi amabili amaqabunga omthofu kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela ama-X-ray
Ukulungiswa kwensimu ye-irradiation kugesi, ukunyakaza kweqabunga lomthofu kuqhutshwa yi-motor stepping, futhi inkambu yokukhanyisa ihlale ilungiswa.
Lawula i-beam limiter ngokusebenzisa ukuxhumana kwebhasi ye-CAN noma ukushintshwa kwezinga, noma lawula ngesandla isikhawuli se-beam esiphambi kwakho, futhi isikrini se-LCD sibonisa isimo nemingcele yomkhawulo we-beam.
Inkambu yokukhanya ebonakalayo isebenzisa ama-LED ama-bulb anokukhanya okuphezulu
Isekhethi yokulibaziseka yangaphakathi ingacisha isibani ngokuzenzakalela ngemva kwamasekhondi angu-30 okukhanya, futhi ingacisha isibani mathupha phakathi nesikhathi sokukhanya ukuze kwelule impilo yesibani futhi yonge amandla.
Uxhumano lwemishini olulula futhi oluthembekile nge-X-ray tube, kulula ukulungisa

I-Medical X-ray Collimator Automatic X-ray Collimator SR305
Ifanele izinto ezijwayelekile zokuxilonga ze-X-ray ezinamashubhu kagesi angu-150kV
Inkundla yokuthela ngemisebe ye-X-ray inonxande
Ukuhambisana namazinga afanele kazwelonke nawemboni
Usayizi omncane
Ukuthembeka okuphezulu nokusebenza kwezindleko eziphezulu
Ukusebenzisa izingqimba ezintathu namasethi amabili amaqabunga omthofu kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela ama-X-ray
Ukulungiswa kwendawo yokuthela kwenziwa ngesandla, futhi inkambu yokuthela imisebe ilungiswa ngokuqhubekayo.
Inkambu yokukhanya ebonakalayo isebenzisa ama-LED ama-bulbs akhanya kakhulu
Isekhethi yokulibaziseka yangaphakathi ingacisha isibani ngokuzenzakalela ngemva kwamasekhondi angu-30 okukhanya, futhi ingacisha isibani mathupha phakathi nesikhathi sokukhanya ukuze kwelule impilo yesibani futhi yonge amandla.
Uxhumano lwemishini olulula futhi oluthembekile nge-X-ray tube, kulula ukulungisa

I-Medical X-ray Collimator Manual X-ray beam limitter SR302
Ifanele izinto ezijwayelekile zokuxilonga ze-X-ray ezinamashubhu kagesi angu-150kV
Inkundla yokuthela ngemisebe ye-X-ray inonxande
Ukuhambisana namazinga afanele kazwelonke nawemboni
Usayizi omncane
Ukuthembeka okuphezulu nokusebenza kwezindleko eziphezulu
Ukusebenzisa izendlalelo ezikabili kanye namasethi amabili amaqabunga omthofu kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela ama-X-ray
Ukulungiswa kwendawo yokuthela kwenziwa ngesandla, futhi inkambu yokuthela imisebe ilungiswa ngokuqhubekayo.
Inkambu yokukhanya ebonakalayo isebenzisa ama-LED ama-bulbs akhanya kakhulu
Isekhethi yokulibaziseka yangaphakathi ingacisha isibani ngokuzenzakalela ngemva kwamasekhondi angu-30 okukhanya, futhi ingacisha isibani mathupha phakathi nesikhathi sokukhanya ukuze kwelule impilo yesibani futhi yonge amandla.
Uxhumano lwemishini olulula futhi oluthembekile nge-X-ray tube, kulula ukulungisa

I-Medical X-ray Collimator Automatic X-ray Collimator 34 SRF202AF
Uhlobo: SRF202AF
Isebenza ku-C ARM
Ibanga eliphezulu lenkambu ye-X-ray: 440mm×440mm
Amandla kagesi aphezulu: 150KV
Usayizi: 60 mm

I-Medical X-ray Collimator Automatic X-ray Collimator SR301
Izici
Ifanele i-tube voltage 150kV, i-DR digital kanye nemishini yokuxilonga ye-X-ray evamile
Inkundla yokuthela ngemisebe ye-X-ray inonxande
Ukuhambisana namazinga afanele kazwelonke nawemboni
Ukuthembeka okuphezulu nokusebenza kwezindleko eziphezulu
Izendlalelo ezikabili kanye namasethi amabili amaqabunga omthofu kanye nesakhiwo esikhethekile sokuzivikela sangaphakathi sisetshenziselwa ukuvikela ama-X-ray. Amaqabunga omthofu aphezulu angangena efasiteleni leshubhu le-X-ray, elingavikela imisebe ehlakazekile elahlekile ngokuphumelelayo.
Ukulungiswa kwenkundla yokuthela imisebe kwenziwa ngesandla, kuyalungiseka ngokuqhubekayo
Inkambu yokukhanya ebonakalayo isebenzisa ama-LED ama-bulbs akhanya kakhulu
Isekhethi yokulibaziseka yangaphakathi ingacisha isibani ngokuzenzakalela ngemva kwamasekhondi angu-30 okukhanya, futhi ingacisha isibani mathupha phakathi nesikhathi sokukhanya ukuze kwelule impilo yesibani futhi yonge amandla.
Uxhumano lwemishini olulula futhi oluthembekile nge-X-ray tube, kulula ukulungisa

I-Medical X-ray Collimator Manual X-ray Collimator SR103
Izici
Ifanele umshini wokuxilonga we-X-ray ophathwayo noma ophathwayo onamandla omthamo weshubhu ongu-120kV
Inkundla yokuthela ngemisebe ye-X-ray inonxande
Ukuhambisana namazinga afanele kazwelonke nawemboni
Usayizi omncane
Ukuthembeka okuphezulu nokusebenza kwezindleko eziphezulu
Ukusebenzisa ungqimba olulodwa namasethi amabili amaqabunga omthofu kanye nesakhiwo esikhethekile sangaphakathi sokuvikela ukuvikela ama-X-ray
Ukulungiswa kwendawo yokuthela kwenziwa ngesandla, futhi inkambu yokuthela imisebe ilungiswa ngokuqhubekayo.
Inkambu yokukhanya ebonakalayo isebenzisa ama-LED ama-bulbs akhanya kakhulu
Uxhumano lwemishini olulula futhi oluthembekile nge-X-ray tube, kulula ukulungisa

I-Medical X-ray Collimator Manual X-ray beam limitter SR202
Izici
Ihambisana nemishini yokuxilonga ye-X-ray esebenzisa amandla kagesi eshubhu angu-150kV, okuhlanganisa nezinhlelo zedijithali ze-DR kanye nezinhlelo ezivamile
Inkundla yokuthela ngemisebe ye-X-ray inonxande
Ukuhambisana namazinga afanele kazwelonke nawemboni
Usayizi omncane
Ukuthembeka okuphezulu nokusebenza kwezindleko eziphezulu
Isebenzisa isendlalelo esisodwa, amasethi amabili amaqabunga omthofu kanye nomklamo okhethekile wokuvikela wangaphakathi ukuvimba ama-X ray.
Ukulungiswa kwenkundla yokuthela imisebe kwenziwa ngesandla, kuyalungiseka ngokuqhubekayo
Inkambu yokukhanya ebonakalayo isebenzisa amalambu e-LED
Isekhethi yokulibaziseka eyakhelwe ngaphakathi icima isibani ngokuzenzakalelayo imizuzwana engama-30 ngemuva kokuqaliswa, futhi inketho yezandla yokucisha ukukhanya phakathi nokusebenza nayo iyatholakala. Lezi zici ziklanyelwe ukunweba impilo yesibani futhi kuncishiswe ukusetshenziswa kwamandla.

Inkinobho yokusunduza ye-X-ray Shintsha Uhlobo lwe-Omron Microswitch 14 HS-01
Imodeli: HS-01
Uhlobo: Ukunyathela okubili
Ukwakhiwa nezinto ezibonakalayo: Nge-Omron micro switch, ikhava yentambo yekhoyili ye-PU kanye nezintambo zethusi
Izintambo nentambo yekhoyili: 3cores noma 4cores, 3m noma 5m noma ubude obungokwezifiso
Ikhebula: 24AWG ikhebula noma 26 AWG
Impilo yemishini: izikhathi eziyizigidi eziyi-1.0
Impilo kagesi: izikhathi eziyizinkulungwane ezingama-400
Isitifiketi: CE, RoHS

75KVDC High Voltage Cable WBX-Z75-T
I-High Voltage Cable Assemblies for X-ray Machines iwukuhlanganiswa kwekhebula lezokwelapha likagesi ophezulu elilinganiselwe kufika ku-100 kVDC, uhlobo lwempilo (ukuguga) oluhlolwe ngaphansi kwezimo ezinzima kakhulu.
Le khondatha engu-3 enekhebula le-90º Plug high voltage cables izinhlelo zokusebenza ezijwayelekile zingokulandelayo:
1, Imishini ye-x-ray yezokwelapha njenge-x-ray evamile, i-computer tomography kanye nemishini ye-angiography.
2, Imishini ye-x ray yezimboni neyesayensi noma insimbi ye-electron efana ne-electron microscopy kanye nemishini ye-x-ray diffraction.
3, Ukuhlolwa kwamandla kagesi aphansi kanye nemishini yokulinganisa.

I-Mammography High Voltage Cable WBX-Z60-T02
Amakhebula anamandla kagesi aphezulu ahlanganisa izintambo ezinamandla kagesi namapulaki
Amakhebuli anamandla kagesi aphezulu aqukethe lezi zingxenye ezilandelayo:
a) Umqhubi;
b) ungqimba oluvikelayo;
c) ungqimba oluvikelayo;
d) Isigodlo.
Ipulaki izoba nezingxenye eziyinhloko ezilandelayo:
a) Izinsimbi;
b) ipulaki umzimba;
c) iphini

I-Anode X-ray Ejikelezayo Amashubhu MWTX70-1.0_2.0-125
Uhlobo: Ishubhu ye-anode x-ray ejikelezayo
Isicelo: Ukuze ukuxilongwa Medical x-ray iyunithi
Imodeli: MWTX70-1.0/2.0-125
Ilingana ne-Toshiba E-7239
Ishubhu yengilazi yekhwalithi ephezulu ehlanganisiwe
Ukugunyazwa kwe-CE

I-Bone Desimeter X-ray Tube Brand Bx-1
Uhlobo: Ishubhu ye-anode ye-x-ray yesiteshi
Isicelo: Idizayinelwe Ikakhulukazi isistimu ye-x-ray ye-bone densimeter ye-radiography.
Imodeli: RT2-0.5-80
Ilingana ne-BRAND X-RAY BX-1
Ishubhu yengilazi yekhwalithi ephezulu ehlanganisiwe